  1. 原著論文

Rejoining kinetics of G1-PCC breaks induced by different heavy-ion beams with a similar LET value.

https://repo.qst.go.jp/records/45884
https://repo.qst.go.jp/records/45884
b8f1ed59-0bdd-4314-af37-fe79d326046e
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-08-25
タイトル
タイトル Rejoining kinetics of G1-PCC breaks induced by different heavy-ion beams with a similar LET value.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tsuruoka, Chizuru

× Tsuruoka, Chizuru

WEKO 456390

Tsuruoka, Chizuru

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 456391

Furusawa, Yoshiya

Search repository
Anzai, Kazunori

× Anzai, Kazunori

WEKO 456392

Anzai, Kazunori

Search repository
Okayasu, Ryuichi

× Okayasu, Ryuichi

WEKO 456393

Okayasu, Ryuichi

Search repository
Suzuki, Masao

× Suzuki, Masao

WEKO 456394

Suzuki, Masao

Search repository
鶴岡 千鶴

× 鶴岡 千鶴

WEKO 456395

en 鶴岡 千鶴

Search repository
古澤 佳也

× 古澤 佳也

WEKO 456396

en 古澤 佳也

Search repository
岡安 隆一

× 岡安 隆一

WEKO 456397

en 岡安 隆一

Search repository
鈴木 雅雄

× 鈴木 雅雄

WEKO 456398

en 鈴木 雅雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 In previous studies we have shown that the linear energy transfer (LET) relative biological effectiveness (RBE) curves were affected by LET and ion species [1,2]. In this paper we have examined the difference in the repair kinetics of G1-prematurely condensed chromosome breaks in normal human fibroblasts following irradiation with different heavy-ion beams of similar LET values. Normal human fibroblasts were irradiated with about 110 keV/micrometer of carbon (135 MeV/n), neon (400 MeV/n) and silicon ions (490 MeV/n), and the doses of carbon (3.25 Gy), neon (2.94 Gy) and silicon (2.31 Gy) were chosen to produce approximately the same number of initially measured G1-premature chromosome condensation (PCC) breaks (about 37 excess fragments per cell). The number of G1-PCC breaks was counted as excess fragments of prematurely condensed chromosomes using the PCC technique in theG1/G0 phase. The fractions
of residual G1-PCC breaks after 24 h post-irradiation and half time, which is the time point where 50% of initially measured G1-PCC breaks are rejoined (t1/2), of the slow components of rejoining in carbon- and neon-ion irradiated cells were different from those of silicon-ion irradiated cells. However, no difference was observed in the half time of the fast components of rejoining in each ion beam. The results suggest that the difference in the fractions of residual G1-PCC breaks after 24 h post-irradiation reflect the result of the slow repair process for induced G1-PCC breaks, and that the repair process is dependent on the ion species, not the LET values.
書誌情報 Genetic Toxicology and Environmental Mutagenesis : A Section of Mutation Research

巻 701, 号 1, p. 47-51, 発行日 2010-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 1383-5718
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:58:26.554664
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3