ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Basic study of entire whole-body PET scanners based on the OpenPET geometry

https://repo.qst.go.jp/records/45881
https://repo.qst.go.jp/records/45881
b2a16b7d-cd4e-48a0-8ec2-889fc29f0882
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-08-19
タイトル
タイトル Basic study of entire whole-body PET scanners based on the OpenPET geometry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshida, Eiji

× Yoshida, Eiji

WEKO 456357

Yoshida, Eiji

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 456358

Yamaya, Taiga

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 456359

Nishikido, Fumihiko

Search repository
Inadama, Naoko

× Inadama, Naoko

WEKO 456360

Inadama, Naoko

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 456361

Murayama, Hideo

Search repository
吉田 英治

× 吉田 英治

WEKO 456362

en 吉田 英治

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 456363

en 山谷 泰賀

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 456364

en 錦戸 文彦

Search repository
稲玉 直子

× 稲玉 直子

WEKO 456365

en 稲玉 直子

Search repository
村山 秀雄

× 村山 秀雄

WEKO 456366

en 村山 秀雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 A conventional PET scanner has a 15–25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.
書誌情報 Nuclear Instruments & Methods in Physics Research Section A

巻 621, 号 1/3, p. 576-580, 発行日 2010-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2010.03.170
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:58:28.696397
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3