Measurement of absorbed dose, quality factor, and dose equivalent in water phantom outside of the irradiation field in passive carbon-ion and proton radiotherapies
https://repo.qst.go.jp/records/45858
https://repo.qst.go.jp/records/45858462f78b2-0d5b-4f40-b23f-cef0b01c6ceb
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-07-15 | |||||
タイトル | ||||||
タイトル | Measurement of absorbed dose, quality factor, and dose equivalent in water phantom outside of the irradiation field in passive carbon-ion and proton radiotherapies | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yonai, Shunsuke
× Yonai, Shunsuke× Kase, Yuki× Matsufuji, Naruhiro× Kanai, Tatsuaki× Nishio, Teiji× Namba, Masao× Yamashita, Wataru× 米内 俊祐× 松藤 成弘× 金井 達明× 西尾 禎治× 難波 将夫× 山下 航 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: Successful results in carbon-ion and proton radiotherapies can extend patients' lives and thus present a treatment option for younger patients; however, the undesired exposure to normal tissues outside the treatment volume is a concern. Organ-specific information on the absorbed dose and the biological effectiveness in the patient is essential for assessing the risk, but experimental dose assessment has seldom been done. In this study, absorbed doses, quality factors, and dose equivalents in water phantom outside of the irradiation field were determined based on lineal energy distributions measured with a commercial tissue equivalent proportional counter (TEPC) at passive carbon-ion and proton radiotherapy facilities. Methods: Measurements at eight positions in the water phantom were carried out at the Heavy-Ion Medical Accelerator in Chiba of the National Institute of Radiological Sciences for 400 and 290 MeV/u carbon beams and at the National Cancer Center Hospital East for a 235 MeV proton beam. Results: The dose equivalent per treatment absorbed dose at the center of the range-modulated region H/Dt decreased as the position became farther from the beam axis and farther from the phantom surface. The values of H/Dt ranged from 6.7 to 0.16 mSv/Gy for the 400 MeV/u carbon beam, from 1.3 to 0.055 mSv/Gy for the 290 MeV/u carbon beam, and from 4.7 to 0.24 mSv/Gy for the 235 MeV proton beam. The values of the dose-averaged quality factor QD ranged from 2.4 to 4.6 for the 400 MeV/u beam, from 2.8 to 5.3 for the 290 MeV/u beam, and from 5.1 to 8.2 for the proton beam. The authors also observed differences in the distributions of H/Dt and QD between the carbon and proton beams. Conclusions: The authors experimentally obtained absorbed doses, dose-averaged quality factors, and dose equivalents in water phantom outside of the irradiation field in passive carbon-ion and proton radiotherapies with TEPC. These data are very useful for estimating the risk of secondary cancer after receiving passive radiotherapies and for verifying Monte Carlo calculations. |
|||||
書誌情報 |
Medical Physics 巻 37, 号 8, p. 4046-4055, 発行日 2008-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0094-2405 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1118/1.3458721 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://online.medphys.org/mphya6/v37/i8/p4046_s1 | |||||
関連名称 | http://online.medphys.org/mphya6/v37/i8/p4046_s1 |