A HTS scanning magnet and AC operation
https://repo.qst.go.jp/records/45800
https://repo.qst.go.jp/records/45800e35aa87c-4938-49ea-a28f-972aa6a6d108
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-06-02 | |||||
タイトル | ||||||
タイトル | A HTS scanning magnet and AC operation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hatanaka, Kichiji
× Hatanaka, Kichiji× Fukuda, Mitsuhiro× Noda, Kouji× et.al× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A scanningmagnetusinghigh-temperaturesuperconductor(HTS) wire was designed, built, and tested for its suitability as a beam scanner. After successful cooling tests, the magnet performance was studied using DC and AC currents. With DC current the magnet was successfully operated to generate designed field distributions and effective length. In AC mode,the magnet was operated at frequencies of 30–59 Hz and a temperature of 77 K as well as 10–20 Hz and 20K.The power losses dissipated in the coils were measured and compared with the modelcalculations. Theo bserved losses per cycle were independent of the frequency and the scaling law of the transport current was consistent with theoretical predictions for hysteretic losses in HTS wires. | |||||
書誌情報 |
Nuclear Instruments & Methods in Physics Research Section A 巻 616, 号 1, p. 16-20, 発行日 2010-04 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 |