WEKO3
アイテム
CT-based 3D Dose-Volume Parameter of the Rectum and Late Rectal Complication in Patients with Cervical Cancer Treated with High-Dose-Rate Intracavitary Brachytherapy
https://repo.qst.go.jp/records/45777
https://repo.qst.go.jp/records/45777868cc45e-8aae-433b-adb2-bbe251f4f727
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-04-02 | |||||
タイトル | ||||||
タイトル | CT-based 3D Dose-Volume Parameter of the Rectum and Late Rectal Complication in Patients with Cervical Cancer Treated with High-Dose-Rate Intracavitary Brachytherapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kato, Shingo
× Kato, Shingo× Dang, Ngoc Linh Tran× Ohno, Tatsuya× Nakano, Takashi× Kiyohara, Hiroki× Ohkubo, Yu× Kamada, Tadashi× 加藤 眞吾× 大野 達也× 清原 浩樹× 大久保 悠× 鎌田 正 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This study evaluated the efficacy of computed tomography (CT)-based three-dimensional (3D) dose-volume parameters of the rectum as predictor for late rectal complication (LRC) in cervical cancer patients treated with radiotherapy alone. Eighty-four patients treated with a combination of external radiotherapy and high-dose-rate intracavitary brachytherapy between January 2000 and December 2004 were retrospectively analyzed. Brachytherapy was prescribed with standard 2D planning. Patients underwent pelvic CT at brachytherapy. The external rectal wall was contoured on the CT images, and the minimum doses delivered to 0.1cc, 1cc, and 2cc of the most irradiated rectal volumes were calculated with dose-volume histograms. The International Commission of Radiation Units and Measurements (ICRU) rectal point dose was also calculated by conventional method. Total dose (external radiotherapy plus brachytherapy) to the rectum was transformed to the biologically equivalent dose in 2-Gy fractions with a/B of 3 Gy (D0.1cc, D1cc, D2cc and DICRU). The relationships between these dosimetric parameters and the incidence of LRC were analyzed. The 5-year overall actuarial rate of LRC was 26.4%. The values of D0.1cc, D1cc, and D2cc were significantly higher in patients with LRC than in those without (p < 0.001), but the difference in the values of DICRU was not statistically significant (p = 0.10). The rate of LRC increased significantly with increasing D0.1cc, D1cc, and D2cc (p = 0.001). However, no positive dose-response relationship was observed between DICRU and the rate of LRC (p = 0.42). The present study has suggested that CT-based 3D dose-volume parameters of the rectum may be effective for predicting LRC. | |||||
書誌情報 |
Journal of Radiation Research 巻 51, 号 2, p. 215-221, 発行日 2010-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0449-3060 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1269/jrr.09118 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jstage.jst.go.jp/browse/jrr/51/2/_contents | |||||
関連名称 | http://www.jstage.jst.go.jp/browse/jrr/51/2/_contents |