Application of monochromatic keV X-ray source to X-ray drug delivery system

https://repo.qst.go.jp/records/45681
https://repo.qst.go.jp/records/45681
c9a3c9c2-5ea0-4fe6-95e8-50dfa112dd3b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-12-11
タイトル
タイトル Application of monochromatic keV X-ray source to X-ray drug delivery system
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Uesaka, Mitsuru

× Uesaka, Mitsuru

WEKO 453954

Uesaka, Mitsuru

Search repository
Taguchi, Hiroki

× Taguchi, Hiroki

WEKO 453955

Taguchi, Hiroki

Search repository
Mori, Azusa

× Mori, Azusa

WEKO 453956

Mori, Azusa

Search repository
Yusa, Noritaka

× Yusa, Noritaka

WEKO 453957

Yusa, Noritaka

Search repository
Kato, Takamitsu

× Kato, Takamitsu

WEKO 453958

Kato, Takamitsu

Search repository
Okayasu, Ryuichi

× Okayasu, Ryuichi

WEKO 453959

Okayasu, Ryuichi

Search repository
上坂 充

× 上坂 充

WEKO 453960

en 上坂 充

Search repository
森 梓

× 森 梓

WEKO 453961

en 森 梓

Search repository
加藤 宝光

× 加藤 宝光

WEKO 453962

en 加藤 宝光

Search repository
岡安 隆一

× 岡安 隆一

WEKO 453963

en 岡安 隆一

Search repository
抄録
内容記述タイプ Abstract
内容記述 X-ray Drug Delivery System (DDS) enhances accumulation of anti-cancer drug or contrast agent by surrounding it with polymer and Enhanced Penetration and Retention (EPR) effect. DDS uses advanced nano-scaled polymers that contain and deliver drug or contrast agent to cancers without side effects. Several X-ray DDSs pose high-Z atoms such as gold to absorb X-rays effectively and used as contrast agent for inspection. Moreover, they have radiation enhancement effect by emission of Auger electron and successive characteristic X-rays. The enhancement factor of gold is more than five. This could be used even for therapy. This new modality must be very important for inspection and therapy of deep cancers. We are making use of our X-band Compton scattering monochromatic keV X-ray source for the inspection. Numerical simulation on monochromatic X-ray CT for possible concentration of gold-colloid DDS considering the X-ray property from the source was done. Enough visibility was confirmed. Furthermore, in vitro experiment analyzed its toxic effect to cells by the Alkaline comet assay and fluorescent immunostaining method for single and double strand breaks of DNA. Availability of clear imaging for the inspection has been confirmed by the numerical simulation and the in-vitro evaluation of the therapy effect is under way. (C) 2009 Elsevier B.V. All rights reserved.
書誌情報 Nuclear Instruments & Methods in Physics Research Section A

巻 608, 号 1, p. S47-S50, 発行日 2009-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
DOI
識別子タイプ DOI
関連識別子 10,1016/j.nima,2009,05,191
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:00:54.874931
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3