  1. 原著論文

Monte Carlo study on secondary neutrons in passive carbon-ion radiotherapy: Identification of the main source and reduction in the secondary neutron dose

https://repo.qst.go.jp/records/45654
https://repo.qst.go.jp/records/45654
0f1ffc08-72f1-4fbf-ab0f-6d9a99ff9de7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-10-01
タイトル
タイトル Monte Carlo study on secondary neutrons in passive carbon-ion radiotherapy: Identification of the main source and reduction in the secondary neutron dose
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yonai, Shunsuke

× Yonai, Shunsuke

WEKO 453659

Yonai, Shunsuke

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 453660

Matsufuji, Naruhiro

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 453661

Kanai, Tatsuaki

Search repository
米内 俊祐

× 米内 俊祐

WEKO 453662

en 米内 俊祐

Search repository
松藤 成弘

× 松藤 成弘

WEKO 453663

en 松藤 成弘

Search repository
金井 達明

× 金井 達明

WEKO 453664

en 金井 達明

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: Recent successful results in passive carbon-ion radiotherapy allow the patient to live for a longer time and allow younger patients to receive the radiotherapy. Undesired radiation exposure in normal tissues far from the target volume is considerably lower than that close to the treatment target, but it is considered to be non-negligible in the estimation of the secondary cancer risk. Therefore, it is very important to reduce the undesired secondary neutron exposure in passive carbon-ion radiotherapy without influencing the clinical beam. In this study, the source components in which the secondary neutrons are produced during passive carbon-ion radiotherapy were identified and the method to reduce the secondary neutron dose effectively based on the identification of the main sources without influencing the clinical beam was investigated.
\nMethods: A Monte Carlo study with the PHITS code was performed by assuming the beamline at the Heavy-Ion Medical Accelerator in Chiba (HIMAC). At first, the authors investigated the main sources of secondary neutrons in passive carbon-ion radiotherapy. Next, they investigated the reduction in the neutron dose with various modifications of the beamline device that is the most dominant in the neutron production. Finally, they investigated the use of an additional shield for the patient.
\nResults: It was shown that the main source is the secondary neutrons produced in the four-leaf collimator (FLC) used as a precollimator at HIAMC, of which contribution in the total neutron ambient dose equivalent is more than 70%. The investigations showed that the modification of the FLC can reduce the neutron dose at positions close to the beam axis by 70% and the FLC is very useful not only for the collimation of the primary beam but also the reduction in the secondary neutrons. Also, an additional shield for the patient is very effective to reduce the neutron dose at positions farther than 50 cm from the beam axis. Finally, they showed that the neutron dose can be reduced by approximately 70% at any position without influencing the primary beam used in treatment.
\nConclusions: This study was performed by assuming the HIMAC beamline; however, this study provides important information for reoptimizing the arrangement and the materials of beamline devices and designing a new facility for passive carbon-ion radiotherapy and probably passive proton radiotherapy.
書誌情報 Medical Physics

巻 36, 号 10, p. 4830-4839, 発行日 2008-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 0094-2405
DOI
識別子タイプ DOI
関連識別子 10.1118/1.3220624
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:01:13.122486
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3