Feasibility study of near-infrared fluorescence tomography using a positron emission tomograph equipped with depth-of-interaction PET detectors

https://repo.qst.go.jp/records/45629
https://repo.qst.go.jp/records/45629
3a092210-5749-4c7f-a61e-0e9dcf758d34
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-09-07
タイトル
タイトル Feasibility study of near-infrared fluorescence tomography using a positron emission tomograph equipped with depth-of-interaction PET detectors
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tashima, Hideaki

× Tashima, Hideaki

WEKO 904404

Tashima, Hideaki

Search repository
Obi, Takashi

× Obi, Takashi

WEKO 904405

Obi, Takashi

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 904406

Yamaya, Taiga

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 904407

Murayama, Hideo

Search repository
Kitamura, Keishi

× Kitamura, Keishi

WEKO 904408

Kitamura, Keishi

Search repository
Oda, Ichiro

× Oda, Ichiro

WEKO 904409

Oda, Ichiro

Search repository
Yamaguchi, Masahiro

× Yamaguchi, Masahiro

WEKO 904410

Yamaguchi, Masahiro

Search repository
Oyama, Nagaaki

× Oyama, Nagaaki

WEKO 904411

Oyama, Nagaaki

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 904412

en Tashima, Hideaki

Search repository
Obi, Takashi

× Obi, Takashi

WEKO 904413

en Obi, Takashi

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 904414

en Yamaya, Taiga

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 904415

en Murayama, Hideo

Search repository
Kitamura, Keishi

× Kitamura, Keishi

WEKO 904416

en Kitamura, Keishi

Search repository
抄録
内容記述タイプ Abstract
内容記述 We are currently developing an imaging system that combines simultaneous positron emission tomography (PET) with near-infrared (NIR) optical tomography, thus supporting two different types of molecular imaging. For this system, we are considering whether to use depth of interaction (DOI) PET detectors as simultaneous detectors of gamma rays and NIR light by changing the original upper reflectors to dichroic mirrors. The DOI-PET detector has very low spatial resolution for NIR light compared to the charge-coupled device cameras that are normally used. However, it is possible to reconstruct images of comparable value from the data acquired by low-resolution devices because the light is scattered by biological tissues and high-resolution devices are not necessarily effective at improving image quality. In this study, we demonstrate the feasibility of 3D NIR fluorescence tomography imaging by employing DOI-PET detectors in computer simulations. In the simulations, we used a 40 mm * 40 mm * 40 mm cubic phantom, a square detector geometry, and an optical diffusion equation to approximate the light propagation. We then evaluated imaging systems for 3D fluorescence tomography with different detector resolutions and excitation light arrangements using singular-value analysis and imaging simulation. We confirmed that the reconstructed images from low-resolution detectors (8 * 8 pixels for an area of 40 mm * 40 mm) are the same as those from high-resolution detectors (16 * 16 pixels for the same area).
書誌情報 Radiological Physics and Technology

巻 2, 号 2, p. 189-197, 発行日 2009-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0333
DOI
識別子タイプ DOI
関連識別子 10.1007/s12194-009-0065-2
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:56:03.724239
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3