ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Optical observation of energy loss distribution and practical range of positrons from a 18F water solution in a water-equivalent phantom

https://repo.qst.go.jp/records/45626
https://repo.qst.go.jp/records/45626
35d9b8bb-ff98-4a6e-a685-96f89afc7e91
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-09-02
タイトル
タイトル Optical observation of energy loss distribution and practical range of positrons from a 18F water solution in a water-equivalent phantom
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hasegawa, Tomoyuki

× Hasegawa, Tomoyuki

WEKO 453429

Hasegawa, Tomoyuki

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 453430

Yoshida, Eiji

Search repository
Shibuya, Kengo

× Shibuya, Kengo

WEKO 453431

Shibuya, Kengo

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 453432

Murayama, Hideo

Search repository
長谷川 智之

× 長谷川 智之

WEKO 453433

en 長谷川 智之

Search repository
吉田 英治

× 吉田 英治

WEKO 453434

en 吉田 英治

Search repository
澁谷 憲悟

× 澁谷 憲悟

WEKO 453435

en 澁谷 憲悟

Search repository
村山 秀雄

× 村山 秀雄

WEKO 453436

en 村山 秀雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 The energy loss distribution of beta+ particles is closely related to their maximum penetration depth distribution and annihilation point distribution. The latter is of practical importance for positron emission tomography. Experimental data related to the energy loss distribution are important for comprehensive validation of physics and simulation models of beta+ interactions. In this paper the authors present a new experimental approach that allows them to visually observe the beta+ energy loss distribution of a solution of nuclear medicine radioisotopes in a plastic scintillator using an optical camera. The authors also report a set of the first experimental results. A water solution of 18F was localized in a small hole in a plastic scintillator (BC430). Optical imaging of the scintillator yielded visual images of the energy loss distribution with a submillimeter resolution. The radial dependence in the energy distribution was quantitatively measured by analysis of the images, and exponential fitting parameters were obtained. The authors observed that the results of Monte Carlo simulation with EGS5 (version 1.0.2) and GEANT4 (version 4.9.01.p01) were consistent with those obtained experimentally. The results of the Monte Carlo simulation indicated that for a linear scale, the energy loss distribution in the scintillator was approximately the same as that in water, and the relative shape of the energy loss distribution was close to those of the maximum penetration depth distribution and annihilation point distribution. This paper also presents discussions about the further possibilities of this optical imaging approach. Thus, optical observation of the brts+ energy loss distribution in a scintillator is a promising technique for visual and quantitative experimental studies of beta+ emission from a solution of radioisotopes that are used in nuclear medicine.
書誌情報 Medical Physics

巻 36, 号 2, p. 402-410, 発行日 2009-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0094-2405
DOI
識別子タイプ DOI
関連識別子 10.1118/1.3054765
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:01:30.949565
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート