ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Biologocal Intercomparison using Gut Crypt Survivals for Proton and Carbon-Ion Beams

https://repo.qst.go.jp/records/45620
https://repo.qst.go.jp/records/45620
78982657-902d-4e55-acae-f760bc1ca7ab
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-08-27
タイトル
タイトル Biologocal Intercomparison using Gut Crypt Survivals for Proton and Carbon-Ion Beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Uzawa, Akiko

× Uzawa, Akiko

WEKO 453358

Uzawa, Akiko

Search repository
Ando, Koichi

× Ando, Koichi

WEKO 453359

Ando, Koichi

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 453360

Furusawa, Yoshiya

Search repository
et.al

× et.al

WEKO 453361

et.al

Search repository
鵜澤 玲子

× 鵜澤 玲子

WEKO 453362

en 鵜澤 玲子

Search repository
安藤 興一

× 安藤 興一

WEKO 453363

en 安藤 興一

Search repository
古澤 佳也

× 古澤 佳也

WEKO 453364

en 古澤 佳也

Search repository
抄録
内容記述タイプ Abstract
内容記述 harged particle therapy depends on biological information for the dose prescription. Relative biological effectiveness or RBE for this requirement could basically be provided by experimental data. As RBE values of protons and carbon ions depend on several factors such as cell/tissue type, biological endpoint, dose and fractionation schedule, a single RBE value could not deal with all different radiosensitivities. However, any biological model with accurate reproducibility is useful for comparing biological effectiveness between different facilities. We used mouse gut crypt survivals as endpoint, and compared the cell killing efficiency of proton beams at three Japanese facilities. Three Linac X-ray machines with 4 and 6 MeV were used as reference beams, and there was only a small variation (coefficient of variance < 2%) in biological effectiveness among them. The RBE values of protons relative to Linac X-rays ranged from 1.0 to 1.11 at the middle of a 6-cm SOBP (spread-out Bragg peak) and from 0.96 to 1.01 at the entrance plateau. The coefficient of variance for protons ranged between 4.0 and 5.1%. The biological comparison of carbon ions showed fairly good agreement in that the difference in biological effectiveness between NIRS/HIMAC and GSI/SIS was 1% for three positions within the 6-cm SOBP. The coefficient of variance was < 1.7, < 0.6 and < 1.6% for proximal, middle and distal SOBP, respectively. We conclude that the inter-institutional variation of biological effectiveness is smaller for carbon ions than protons, and that beam-spreading methods of carbon ions do not critically influence gut crypt survival.
書誌情報 Journal of Radiation Research

巻 48, 号 Supplement A, p. A75-A80, 発行日 2007-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:01:35.302893
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3