  1. 原著論文

Development of an irradiation method with lateral modulation of SOBP width using a cone-type filter for carbon ion beams

https://repo.qst.go.jp/records/45607
https://repo.qst.go.jp/records/45607
43fe2ea0-1ebc-4690-9eff-058b69c4356c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-08-10
タイトル
タイトル Development of an irradiation method with lateral modulation of SOBP width using a cone-type filter for carbon ion beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ishizaki, Azusa

× Ishizaki, Azusa

WEKO 453172

Ishizaki, Azusa

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 453173

Kanematsu, Nobuyuki

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 453174

Kanai, Tatsuaki

Search repository
Yonai, Shunsuke

× Yonai, Shunsuke

WEKO 453175

Yonai, Shunsuke

Search repository
Takei, Yuka

× Takei, Yuka

WEKO 453176

Takei, Yuka

Search repository
Kase, Yuuki

× Kase, Yuuki

WEKO 453177

Kase, Yuuki

Search repository
Komori, Masataka

× Komori, Masataka

WEKO 453178

Komori, Masataka

Search repository
et.al

× et.al

WEKO 453179

et.al

Search repository
石崎 梓

× 石崎 梓

WEKO 453180

en 石崎 梓

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 453181

en 兼松 伸幸

Search repository
金井 達明

× 金井 達明

WEKO 453182

en 金井 達明

Search repository
米内 俊祐

× 米内 俊祐

WEKO 453183

en 米内 俊祐

Search repository
武井 由佳

× 武井 由佳

WEKO 453184

en 武井 由佳

Search repository
加瀬 優紀

× 加瀬 優紀

WEKO 453185

en 加瀬 優紀

Search repository
小森 雅孝

× 小森 雅孝

WEKO 453186

en 小森 雅孝

Search repository
抄録
内容記述タイプ Abstract
内容記述 Passive irradiation methods deliver an extra dose to normal tissues upstream of the target tumor, while in dynamic irradiation methods, interplay effects between dynamic beam delivery and target motion induced by breathing or respiration distort the dose distributions. To solve the problems of those two irradiation methods, the authors have developed a new method that laterally modulates the spread-out Bragg peak (SOBP) width. By reducing scanning in the depth direction, they expect to reduce the interplay effects. They have examined this new irradiation method experimentally. In this system, they used a cone-type filter that consisted of 400 cones in a grid of 20 cones by 20 cones. There were five kinds of cones with different SOBP widths arranged on the frame two dimensionally to realize lateral SOBP modulation. To reduce the number of steps of cones, they used a wheel-type filter to make minipeaks. The scanning intensity was modulated for each SOBP width with a pair of scanning magnets. In this experiment, a stepwise dose distribution and spherical dose distribution of 60 mm in diameter were formed. The nonflatness of the stepwise dose distribution was 5.7% and that of the spherical dose distribution was 3.8%. A 2 mm misalignment of the cone-type filter resulted in a nonflatness of more than 5%. Lateral SOBP modulation with a cone-type filter and a scanned carbon ion beam successfully formed conformal dose distribution with nonflatness of 3.8% for the spherical case. The cone-type filter had to be set to within 1 mm accuracy to maintain nonflatness within 5%. This method will be useful to treat targets moving during breathing and targets in proximity to important organs.
書誌情報 Medical Physics

巻 36, 号 6, p. 2222-2227, 発行日 2009-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0094-2405
DOI
識別子タイプ DOI
関連識別子 10.1118/1.3130021
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:01:44.216847
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3