Proton Beam Therapy Interference with Implanted Cardiac Pacemakers

https://repo.qst.go.jp/records/45601
https://repo.qst.go.jp/records/45601
efb8e762-b52c-4951-8f94-eea73472df09
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-08-06
タイトル
タイトル Proton Beam Therapy Interference with Implanted Cardiac Pacemakers
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Oshiro, Yoshiko

× Oshiro, Yoshiko

WEKO 453132

Oshiro, Yoshiko

Search repository
Sugahara, Shinji

× Sugahara, Shinji

WEKO 453133

Sugahara, Shinji

Search repository
et.al

× et.al

WEKO 453134

et.al

Search repository
菅原 信二

× 菅原 信二

WEKO 453135

en 菅原 信二

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. METHODS AND MATERIALS: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined before and after PBT. RESULTS: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. CONCLUSIONS: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT.
書誌情報 International Journal of Radiation Oncology Biology Physics

巻 72, 号 3, p. 723-727, 発行日 2008-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0360-3016
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:01:48.397688
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3