Measurement of cerebral blood flow by the autoradiographic method with N-isopropyl-4-[I-123] iodoamphetamine: comparison of radiopharmaceuticals marketed by different companies in Japan.

https://repo.qst.go.jp/records/45582
https://repo.qst.go.jp/records/45582
d3b2c4ef-715f-4799-a24d-e37d9ef924d0
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-07-17
タイトル
タイトル Measurement of cerebral blood flow by the autoradiographic method with N-isopropyl-4-[I-123] iodoamphetamine: comparison of radiopharmaceuticals marketed by different companies in Japan.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ogura, Toshiyuki

× Ogura, Toshiyuki

WEKO 452939

Ogura, Toshiyuki

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 452940

Ito, Hiroshi

Search repository
et.al

× et.al

WEKO 452941

et.al

Search repository
伊藤 浩

× 伊藤 浩

WEKO 452942

en 伊藤 浩

Search repository
抄録
内容記述タイプ Abstract
内容記述 OBJECTIVE: Iodine-123-labeled N-isopropyl-4-iodoamphetamine (IMP) is used as a tracer for the measurement of cerebral blood flow (CBF) by single-photon emission computed tomography (SPECT). Two IMP products, IMP(A) (Nihon Medi-Physics Co., Ltd.) and IMP(B) (FUJIFILM RI Pharma Co., Ltd.), produced by different radiopharmaceutical companies are marketed for clinical use in Japan. Although no significant difference in whole-body distribution between the two products has been reported, a significant difference in the radioactivity of the octanol-extracted fraction in whole blood between the two products has been reported in humans. In this study, CBF values obtained by the autoradiographic (ARG) method obtained from both IMP(A) and IMP(B) were compared in the same human subjects. METHODS: SPECT studies were performed on 6 healthy subjects with the use of both IMP(A) and IMP(B). Standard input functions used in the ARG method were obtained for both IMP(A) and IMP(B) from 5 additional healthy subjects. RESULTS: Significant differences were found between CBF values when SPECT data with IMP(A) was combined with the standard input function for IMP(B) (37.7 +/- 3.7 mL/100 g/min at a mid-scan time of 30 min) and SPECT data with IMP(B) was combined with the standard input function for IMP(A) (50.7 +/- 8.9 mL/100 g/min). Nearly the same CBF values were found when SPECT data with IMP(A) was combined with the standard input function for IMP(A) (43.1 +/- 4.4 mL/100 g/min) and SPECT data with IMP(B) was combined with the standard input function for IMP(B) (44.2 +/- 7.6 mL/100 g/min). CONCLUSIONS: Our results suggest that the appropriate standard input function should be used, according to the IMP product used, in the calculation of CBF by the ARG method.
書誌情報 Annals of Nuclear Medicine

巻 23, 号 4, p. 355-361, 発行日 2009-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:02:01.473557
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3