ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Fluctuation in energy-loss measurements in allene-doped liquid argon for heavy ions

https://repo.qst.go.jp/records/45570
https://repo.qst.go.jp/records/45570
36ebfef4-fece-4c1a-8609-bd27485426a5
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-07-06
タイトル
タイトル Fluctuation in energy-loss measurements in allene-doped liquid argon for heavy ions
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Masuda, Kimiaki

× Masuda, Kimiaki

WEKO 452841

Masuda, Kimiaki

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 452842

Nishikido, Fumihiko

Search repository
Shibamura, Eido

× Shibamura, Eido

WEKO 452843

Shibamura, Eido

Search repository
Kikuchi, Jun

× Kikuchi, Jun

WEKO 452844

Kikuchi, Jun

Search repository
Doke, Tadayoshi

× Doke, Tadayoshi

WEKO 452845

Doke, Tadayoshi

Search repository
Murakami, Takeshi

× Murakami, Takeshi

WEKO 452846

Murakami, Takeshi

Search repository
増田 公明

× 増田 公明

WEKO 452847

en 増田 公明

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 452848

en 錦戸 文彦

Search repository
菊池 順

× 菊池 順

WEKO 452849

en 菊池 順

Search repository
道家 忠義

× 道家 忠義

WEKO 452850

en 道家 忠義

Search repository
村上 健

× 村上 健

WEKO 452851

en 村上 健

Search repository
抄録
内容記述タイプ Abstract
内容記述 Liquid argon (LAr) has suitable properties for use as a particle-detector medium, however, its response to heavy ions is not linear, because of the non-perfect collection of charge produced by the incident ions due to the strong recombination between the liberated electrons and argon ions. We were able to improve the linearity of the response by doping photoionization materials, such as allene (C3H4), to LAr. Using allene-doped LAr, we made some experiments of the heavy ion calorimeters for the mass identification of relativistic iron ions, but this approach was unsuccessful. We therefore investigated the cause of the failure using relativistic heavy ions of neon, argon and iron. The energy resolutions obtained experimentally were of the order of several percent at the full width at half maximum (FWHM) for neon to iron ions passing through a LAr gap of 10 mm. These values were 2 or 3 times worse than those predicted theoretically, and the poor energy resolution led to insufficient mass resolution. Here, we describe methods for measuring fluctuation in energy-loss signals in LAr, and discuss the factors determining the resolution.
書誌情報 Nuclear Instruments & Methods in Physics Research Section A

巻 570, 号 3, p. 487-497, 発行日 2006-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2006.10.189
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:02:09.624852
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3