ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

A phantom study on component segregation for MR images using ICA(1)

https://repo.qst.go.jp/records/45562
https://repo.qst.go.jp/records/45562
c266ab8b-bc2f-487a-836e-963edd630d7c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-07-01
タイトル
タイトル A phantom study on component segregation for MR images using ICA(1)
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Miyakoshi, Makoto

× Miyakoshi, Makoto

WEKO 452732

Miyakoshi, Makoto

Search repository
Tomiyasu, Moyoko

× Tomiyasu, Moyoko

WEKO 452733

Tomiyasu, Moyoko

Search repository
Nakai, Toshiharu

× Nakai, Toshiharu

WEKO 452734

Nakai, Toshiharu

Search repository
et.al

× et.al

WEKO 452735

et.al

Search repository
富安 もよこ

× 富安 もよこ

WEKO 452736

en 富安 もよこ

Search repository
抄録
内容記述タイプ Abstract
内容記述 RATIONALE AND OBJECTIVES: A phantom set was devised to evaluate capability of independent component analysis (ICA) as an image filter for magnetic resonance (MR) images to segregate components.
\nMATERIALS AND METHODS: Four components (free water [FW], olive oil [OL], 2% and 4% agar gels [2A and 4A, respectively]) were arranged in a phantom set. Seven MR images were obtained with different echo time and repetition time. ICA was performed on 23 combinations of four components. A segregation rate higher than 70% was defined as effective.
\nRESULTS: Four-component segregation was obtained in 5 of 23 combinations. The best result showed a mean of 87% across the four components. For each component, there were 20 of 23 for FW, 22 for OL, 9 for 2A, and 16 for 4A.
\nCONCLUSIONS: The results demonstrated ICA works as an image filter and provides new contrast images that unambiguously segregate components in MR images. For practical application, the best performance should be obtained when T(1)W, T(2)W, and proton density images are included in the dataset for ICA.
書誌情報 Academic Radiology

巻 16, 号 8, p. 1025-1028, 発行日 2009-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 1076-6332
DOI
識別子タイプ DOI
関連識別子 10.1016/j.acra.2009.02.011
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:02:15.348983
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3