ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Clinical Value of Image Fusion from MR and PET in Patients with Head and Neck Cancer.

https://repo.qst.go.jp/records/45551
https://repo.qst.go.jp/records/45551
84abd92f-c494-48db-98d9-2b512f325043
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-06-24
タイトル
タイトル Clinical Value of Image Fusion from MR and PET in Patients with Head and Neck Cancer.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakamoto, Yuji

× Nakamoto, Yuji

WEKO 452640

Nakamoto, Yuji

Search repository
Tamai, Ken

× Tamai, Ken

WEKO 452641

Tamai, Ken

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 452642

Saga, Tsuneo

Search repository
Higashi, Tatsuya

× Higashi, Tatsuya

WEKO 452643

Higashi, Tatsuya

Search repository
Hara, Tadashi

× Hara, Tadashi

WEKO 452644

Hara, Tadashi

Search repository
Suga, Tsuyoshi

× Suga, Tsuyoshi

WEKO 452645

Suga, Tsuyoshi

Search repository
Koyama, Takashi

× Koyama, Takashi

WEKO 452646

Koyama, Takashi

Search repository
Togashi, Kaori

× Togashi, Kaori

WEKO 452647

Togashi, Kaori

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 452648

en 佐賀 恒夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE: This study aimed to evaluate the clinical value of image fusion from magnetic resonance (MR) combined with positron emission tomography (PET) imaging, using 2-deoxy-2-[F-18]fluoro-D-glucose (FDG) in head and neck cancer. METHODS: Sixty-five consecutive patients underwent MR and FDG-PET scans before or after the treatment of known or suspected head and neck cancer. T1-weighted and T2-weighted images were first assessed by MR interpretation, and then, the fused images of T2-weighted images from MR and PET were evaluated in a blind manner. Diagnostic performance was compared. PROCEDURES: For initial staging, in 48 patients, malignant tumors were histologically confirmed in 45 patients. The interpretation sensitivities of MR alone and fused images for primary tumors were 98% and 100%, respectively. For lymph node metastasis, the sensitivity and specificity of both methods were 85% and 92%, respectively. Of 15 patients with suspected recurrence, ten patients had recurrent tumors, three patients developed second malignant tumors, and two patients had no recurrence. For these patients, the overall sensitivity of MR alone was 67%, whereas that of the fused images was 92%. Eight additional lesions were accurately diagnosed by image fusion only. In two patients with lymph node metastasis from unknown origin, the primary site was not detected in one patient, while tonsilar cancer was identified only by image fusion interpretation. CONCLUSION: Image fusion from MR with PET might be useful in evaluating head and neck cancer, especially in suspected recurrent cases rather than in fresh cases.
書誌情報 Molecular Imaging and Biology

巻 11, 号 1, p. 46-53, 発行日 2008-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 1536-1632
DOI
識別子タイプ DOI
関連識別子 10.1007/s11307-008-0168-x
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:02:22.947437
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3