ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Air Contamination Analysis during Emergency Medical Treatment

https://repo.qst.go.jp/records/45519
https://repo.qst.go.jp/records/45519
2a89aa3e-fbf7-4a3d-806e-97b8f6b87ac0
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-05-29
タイトル
タイトル Air Contamination Analysis during Emergency Medical Treatment
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamada, Yuji

× Yamada, Yuji

WEKO 452268

Yamada, Yuji

Search repository
Fukutsu, Kumiko

× Fukutsu, Kumiko

WEKO 452269

Fukutsu, Kumiko

Search repository
Yuuki, Masanori

× Yuuki, Masanori

WEKO 452270

Yuuki, Masanori

Search repository
Akashi, Makoto

× Akashi, Makoto

WEKO 452271

Akashi, Makoto

Search repository
山田 裕司

× 山田 裕司

WEKO 452272

en 山田 裕司

Search repository
福津 久美子

× 福津 久美子

WEKO 452273

en 福津 久美子

Search repository
結城 政則

× 結城 政則

WEKO 452274

en 結城 政則

Search repository
明石 真言

× 明石 真言

WEKO 452275

en 明石 真言

Search repository
抄録
内容記述タイプ Abstract
内容記述 After radiological emergencies, patients contaminated with radioactivity are taken to radiation emergency hospitals for treatment. Numerical simulations using the computer software 'Flow Designer' were made in order to evaluated indoor air contamination caused by the breathing out of contaminated air. The National Institute of Radiological Sciences facility was used for the numerical evaluation. Results indicate that the dispersion of contaminated air depends on the characteristics of the contaminants, and the dispersion range was limited and localised. Only medical staff standing in a special position near the patient was exposed to almost undiluted contaminated air. Highly contaminated air was evacuated with a local exhaust pump system. Room air quality was monitored using a continuous air sampling system, but it was found that the sampling point was not representative for the purpose of radiation protection. From the air-flow analysis, some problems that affect radiological safety were revealed and valuable information and measures for preventing secondary contamination were determined.
書誌情報 Radiation Protection Dosimetry

巻 134, 号 2, p. 113-121, 発行日 2009-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:02:46.324525
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3