  1. 原著論文

Development of a real-time beam current monitoring system for microbeam scanning-PIXE analysis using a ceramic channel electron multiplier

https://repo.qst.go.jp/records/45510
https://repo.qst.go.jp/records/45510
f73fd991-277b-403c-801e-33cdf1c46b79
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-05-14
タイトル
タイトル Development of a real-time beam current monitoring system for microbeam scanning-PIXE analysis using a ceramic channel electron multiplier
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ishikawa, Takahiro

× Ishikawa, Takahiro

WEKO 452194

Ishikawa, Takahiro

Search repository
Iso, Hiroyuki

× Iso, Hiroyuki

WEKO 452195

Iso, Hiroyuki

Search repository
Oikawa, Masakazu

× Oikawa, Masakazu

WEKO 452196

Oikawa, Masakazu

Search repository
Konishi, Teruaki

× Konishi, Teruaki

WEKO 452197

Konishi, Teruaki

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 452198

Kitamura, Hisashi

Search repository
Higuchi, Yuichi

× Higuchi, Yuichi

WEKO 452199

Higuchi, Yuichi

Search repository
Suya, Noriyoshi

× Suya, Noriyoshi

WEKO 452200

Suya, Noriyoshi

Search repository
Hamano, Tsuyoshi

× Hamano, Tsuyoshi

WEKO 452201

Hamano, Tsuyoshi

Search repository
Imaseki, Hitoshi

× Imaseki, Hitoshi

WEKO 452202

Imaseki, Hitoshi

Search repository
石川 剛弘

× 石川 剛弘

WEKO 452203

en 石川 剛弘

Search repository
磯 浩之

× 磯 浩之

WEKO 452204

en 磯 浩之

Search repository
及川 将一

× 及川 将一

WEKO 452205

en 及川 将一

Search repository
小西 輝昭

× 小西 輝昭

WEKO 452206

en 小西 輝昭

Search repository
北村 尚

× 北村 尚

WEKO 452207

en 北村 尚

Search repository
樋口 有一

× 樋口 有一

WEKO 452208

en 樋口 有一

Search repository
酢屋 徳啓

× 酢屋 徳啓

WEKO 452209

en 酢屋 徳啓

Search repository
濱野 毅

× 濱野 毅

WEKO 452210

en 濱野 毅

Search repository
今関 等

× 今関 等

WEKO 452211

en 今関 等

Search repository
抄録
内容記述タイプ Abstract
内容記述 Microbeam scanning-PIXE (micro-PIXE) analysis is a useful method for obtaining information of multi-elemental distribution in samples by two-dimensional images of sample surfaces such as mammalian cells, tissues, and other environmental monitoring species. In addition to elemental distribution information, quantitative analysis is in demand for further investigations of environmental and biomedical studies concerning heavy metals accumulated in terms of cells and sub-cellular organelles. To make quantitative analysis possible, a real-time beam monitoring system that gives a precise number of ions, and an output independent from a sample that enables one to keep a beam resolution of micrometer size is required. In this paper, we report on the development of beam current monitoring. The beam current was monitored using a ceramic channel electron multiplier (CEM) to detect secondary electrons induced from a 50 nm thick carbon film (10 ug/cm2). This carbon film was attached to a sample holder, which was set at the targeted sample position. The output value of the CEM was proportional to the Faraday cup installed just after the sample position. The beam resolution was measured using off-axis STIM by scanning a copper grid, and was estimated at 1.79 and 1.72 um for the horizontal and vertical directions, respectively, sufficient for routine micro-PIXE analysis.
書誌情報 Nuclear Instruments & Methods in Physics Research Section B

巻 267, 号 12/13, p. 2032-2035, 発行日 2009-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-583X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nimb.2009.03.011
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:02:53.151256
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3