DNA fragmentation induced in human fibroblasts by 56Fe ions: experimental data and Monte Carlo simulations

https://repo.qst.go.jp/records/45508
https://repo.qst.go.jp/records/45508
f355b8a5-ea92-4dd3-9f08-a8b745322e66
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-05-14
タイトル
タイトル DNA fragmentation induced in human fibroblasts by 56Fe ions: experimental data and Monte Carlo simulations
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Campa, A

× Campa, A

WEKO 452184

Campa, A

Search repository
Belli, Mauro

× Belli, Mauro

WEKO 452185

Belli, Mauro

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 452186

Furusawa, Yoshiya

Search repository
et.al

× et.al

WEKO 452187

et.al

Search repository
古澤 佳也

× 古澤 佳也

WEKO 452188

en 古澤 佳也

Search repository
抄録
内容記述タイプ Abstract
内容記述 We studied the DNA fragmentation induced in human fibroblasts by iron-ion beams of two different energies: 115 MeV/nucleon and 414 MeV/nucleon. Experimental data were obtained in the fragment size range 1-5700 kbp; Monte Carlo simulations were performed with the PARTRAC code; data analysis was also performed through the Generalized Broken Stick (GBS) model. The comparison between experimental and simulated data for the number of fragments produced in two different size ranges, 1-23 kbp and 23-5700 kbp, gives a satisfactory agreement for both radiation qualities. The Monte Carlo simulations also allow the counting of fragments outside the experimental range: The number of fragments smaller than 1 kbp is large for both beams, although with a strong difference between the two cases. As a consequence, we can compute different RBEs depending on the size range considered for the fragment counting. The PARTRAC evaluation takes into account fragments of all sizes, while the evaluation from the experimental data considers only the fragments in the range of 1-5700 kbp. When the PARTRAC evaluation is restricted to this range, the agreement between experimental and computed RBE values is again good. When fragments smaller than 1 kbp are also considered, the RBE increases considerably, since gamma rays produce a small number of such fragments. The analysis performed with the GBS model proved to be quite sensitive to showing, with a phenomenological single parameter, variations in double-strand break (DSB) correlation.
書誌情報 Radiation Research

巻 171, 号 4, p. 438-445, 発行日 2009-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0033-7587
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:02:55.057459
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3