WEKO3
アイテム
Assessment of cervical lymph node metastases using FDG-PET in patients with head and neck cancer
https://repo.qst.go.jp/records/45478
https://repo.qst.go.jp/records/454788a151b0a-259c-47d5-a502-6d82e487d07a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-04-14 | |||||
タイトル | ||||||
タイトル | Assessment of cervical lymph node metastases using FDG-PET in patients with head and neck cancer | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yamazaki, Yutaka
× Yamazaki, Yutaka× Notani, Ken-ichi× Tei, Kanchu× Totsuka, Yasunori× Takinami, Shu-ichi× Kanegae, Kakuko× Inubushi, Masayuki× Kitagawa, Yoshimasa× et.al× 犬伏 正幸 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Objective To evaluate the diagnostic accuracy of fluorodeoxyglucose positron emission tomography(FDG-PET) relative to computed tomography (CT) for detecting metastatic cervical lymph nodes in patients with squamous cell carcinoma of the head and neck (HNSCC), and to ascertain the factors that affect this accuracy. Methods A total of 1076 lymph nodes obtained from 35 neck dissections in 26 HNSCC patients who preoperatively underwent both FDG-PET and CT were retrospectively analyzed. For pathological metastatic lymphnodes, the lymph node size (short-axis diameter), theratio of intranodal tumor deposits, and the size of intranodaltumor deposits (maximum diameter of metastaticfoci in each lymph node) were histologically recorded.Results Forty-six lymph nodes from 23 neck sides were pathologically diagnosed metastases. The sensitivity, specifi city, accuracy, positive predictive value, and negative predictive value of FDG-PET evaluated individually per neck side were 74%, 92%, 80%, 94%, and 65%, respectively, whereas those of CT were 78%, 58%, 71%, 78%, and 58%, respectively. FDG-PET detected 100% of metastatic lymph nodes ≥10 mm, intranodal tumor deposits ≥9 mm, and intranodal tumor deposits with a ratio >75%, whereas no nodes or tumor deposits smaller than 5 mm were detected. The spatial resolution limitations of FDG-PET were responsible for 16 of 20 (80%) false-negative PET results in lymph nodes. Conclusions FDG-PET is a useful tool for preoperative evaluation of the neck because it accurately detects metastatic lymph nodes ≥10 mm and has fewer false-positive cases than CT. The high specifi city of FDG-PET for lymph node metastases may play an important role in avoiding unnecessary neck dissection. |
|||||
書誌情報 |
Annals of Nuclear Medicine 巻 22, 号 3, p. 177-184, 発行日 2008-05 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-7187 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12149-007-0097-9 |