ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Assessment of cervical lymph node metastases using FDG-PET in patients with head and neck cancer

https://repo.qst.go.jp/records/45478
https://repo.qst.go.jp/records/45478
8a151b0a-259c-47d5-a502-6d82e487d07a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-04-14
タイトル
タイトル Assessment of cervical lymph node metastases using FDG-PET in patients with head and neck cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamazaki, Yutaka

× Yamazaki, Yutaka

WEKO 451875

Yamazaki, Yutaka

Search repository
Notani, Ken-ichi

× Notani, Ken-ichi

WEKO 451876

Notani, Ken-ichi

Search repository
Tei, Kanchu

× Tei, Kanchu

WEKO 451877

Tei, Kanchu

Search repository
Totsuka, Yasunori

× Totsuka, Yasunori

WEKO 451878

Totsuka, Yasunori

Search repository
Takinami, Shu-ichi

× Takinami, Shu-ichi

WEKO 451879

Takinami, Shu-ichi

Search repository
Kanegae, Kakuko

× Kanegae, Kakuko

WEKO 451880

Kanegae, Kakuko

Search repository
Inubushi, Masayuki

× Inubushi, Masayuki

WEKO 451881

Inubushi, Masayuki

Search repository
Kitagawa, Yoshimasa

× Kitagawa, Yoshimasa

WEKO 451882

Kitagawa, Yoshimasa

Search repository
et.al

× et.al

WEKO 451883

et.al

Search repository
犬伏 正幸

× 犬伏 正幸

WEKO 451884

en 犬伏 正幸

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objective To evaluate the diagnostic accuracy of fluorodeoxyglucose positron emission tomography(FDG-PET) relative to computed tomography (CT) for detecting metastatic cervical lymph nodes in patients with squamous cell carcinoma of the head and neck (HNSCC), and to ascertain the factors that affect this accuracy.
Methods A total of 1076 lymph nodes obtained from 35 neck dissections in 26 HNSCC patients who preoperatively underwent both FDG-PET and CT were retrospectively
analyzed. For pathological metastatic lymphnodes, the lymph node size (short-axis diameter), theratio of intranodal tumor deposits, and the size of intranodaltumor deposits (maximum diameter of metastaticfoci in each lymph node) were histologically recorded.Results Forty-six lymph nodes from 23 neck sides were
pathologically diagnosed metastases. The sensitivity, specifi city, accuracy, positive predictive value, and negative predictive value of FDG-PET evaluated individually per neck side were 74%, 92%, 80%, 94%, and 65%, respectively, whereas those of CT were 78%, 58%, 71%, 78%, and 58%, respectively. FDG-PET detected 100%
of metastatic lymph nodes ≥10 mm, intranodal tumor deposits ≥9 mm, and intranodal tumor deposits with a ratio >75%, whereas no nodes or tumor deposits smaller than
5 mm were detected. The spatial resolution limitations of FDG-PET were responsible for 16 of 20 (80%) false-negative PET results in lymph nodes.
Conclusions FDG-PET is a useful tool for preoperative evaluation of the neck because it accurately detects metastatic lymph nodes ≥10 mm and has fewer false-positive cases than CT. The high specifi city of FDG-PET for lymph node metastases may play an important role in avoiding unnecessary neck dissection.
書誌情報 Annals of Nuclear Medicine

巻 22, 号 3, p. 177-184, 発行日 2008-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
DOI
識別子タイプ DOI
関連識別子 10.1007/s12149-007-0097-9
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:03:15.765064
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3