ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Simplified simulation of four-layer depth of interaction detector for PET

https://repo.qst.go.jp/records/45471
https://repo.qst.go.jp/records/45471
241839b9-2103-4699-8617-855afafe5d0d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-04-07
タイトル
タイトル Simplified simulation of four-layer depth of interaction detector for PET
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Haneishi, Hideaki

× Haneishi, Hideaki

WEKO 451816

Haneishi, Hideaki

Search repository
Sato, Masanobu

× Sato, Masanobu

WEKO 451817

Sato, Masanobu

Search repository
Inadama, Naoko

× Inadama, Naoko

WEKO 451818

Inadama, Naoko

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 451819

Murayama, Hideo

Search repository
羽石 秀昭

× 羽石 秀昭

WEKO 451820

en 羽石 秀昭

Search repository
佐藤 允信

× 佐藤 允信

WEKO 451821

en 佐藤 允信

Search repository
稲玉 直子

× 稲玉 直子

WEKO 451822

en 稲玉 直子

Search repository
村山 秀雄

× 村山 秀雄

WEKO 451823

en 村山 秀雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 A four-layer depth-of-interaction (DOI) detector was proposed from and developed at the research project at the National Institute of Radiological Sciences in Japan, with the aim of achieving high resolution and high spatial sensitivity. Previously, we had developed a Monte Carlo simulation for a DOI detector with 2 x 2 x 4 crystal elements. In this study, in order to simulate the final version of the DOI detector of the project, which uses a larger number of crystal elements, we have developed a much faster and simpler simulator. In this paper the algorithm of the simplified simulator as well as the previously proposed Monte Carlo method is presented and the validation of the simplified simulator through comparisons with the full Monte Carlo simulation and with some experimental results is described.
書誌情報 Radiological Physics and Technology

巻 1, 号 1, p. 106-114, 発行日 2007-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0333
DOI
識別子タイプ DOI
関連識別子 10.1007/s12194-007-0017-7
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:03:20.591400
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3