WEKO3
アイテム
{"_buckets": {"deposit": "47809196-c3f9-4a08-92d4-6cf187b87b96"}, "_deposit": {"created_by": 1, "id": "45450", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45450"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045450", "sets": ["1"]}, "author_link": ["451568", "451581", "451570", "451584", "451575", "451586", "451571", "451580", "451577", "451574", "451572", "451576", "451582", "451583", "451585", "451569", "451567", "451573", "451579", "451578"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "69", "bibliographicPageStart": "62", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "Radiological Physics and Technology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have proposed a new \"OpenPET\" geometry consisting of two detector rings of axial length W each separated by a gap G. For obtaining an axially continuous field of view (FOV) of 2W ? G, the maximum limit for G must be W. \nHowever, two valleys of sensitivity appear on both sides of the gap. Setting a more limited range for the gap as GW, which is desirable for filling in the sensitivity\nvalleys, results in not only a shortened gap, but also a shortened axial FOV. \nIn this paper, we propose an alternative method for improving the uniformity of sensitivity by shifting two detector rings axially closer or further apart at the same velocity to each other. \nIn addition, image reconstruction of the OpenPET is an incomplete problem,\nand low-frequency components are missing in the gap.\nTherefore, the proposed method is also expected to improve the conditions for the inverse problem. We simulated an OpenPET scanner which measures events\nsimultaneously by shifting the detector rings. \nThe results showed that the right and left peaks of the sensitivity approach each other upon shifting of the detector rings, and these valleys of sensitivity are effectively recovered. \nThe results also showed that distortion, which is observed for objects containing low-frequency components, is reduced. Larger detector shifts allow a more uniform axial distribution of sensitivity and a higher image quality, but at the cost of a smaller minimum gap. \nTherefore, an appropriate detector-shifting pattern should be determined based on the desired scanner application.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s12194-008-0046-x", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1865-0333", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "451567", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inaniwa, Taku"}], "nameIdentifiers": [{"nameIdentifier": "451568", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "451569", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furukawa, Takuji"}], "nameIdentifiers": [{"nameIdentifier": "451570", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Minohara, Shinichi"}], "nameIdentifiers": [{"nameIdentifier": "451571", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "451572", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko"}], "nameIdentifiers": [{"nameIdentifier": "451573", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shibuya, Kengo"}], "nameIdentifiers": [{"nameIdentifier": "451574", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inadama, Naoko"}], "nameIdentifiers": [{"nameIdentifier": "451575", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murayama, Hideo"}], "nameIdentifiers": [{"nameIdentifier": "451576", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451577", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲庭 拓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451578", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451579", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 卓司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451580", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蓑原 伸一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451581", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451582", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦戸 文彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451583", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "澁谷 憲悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451584", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲玉 直子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451585", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山 秀雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "451586", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Imaging simulations of an \"OpenPET\" geometry with shifting detector rings", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Imaging simulations of an \"OpenPET\" geometry with shifting detector rings"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45450", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-03-25"}, "publish_date": "2009-03-25", "publish_status": "0", "recid": "45450", "relation": {}, "relation_version_is_last": true, "title": ["Imaging simulations of an \"OpenPET\" geometry with shifting detector rings"], "weko_shared_id": -1}
Imaging simulations of an "OpenPET" geometry with shifting detector rings
https://repo.qst.go.jp/records/45450
https://repo.qst.go.jp/records/45450efb7f2a1-e7a5-4607-8824-d6e1eb329850
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-03-25 | |||||
タイトル | ||||||
タイトル | Imaging simulations of an "OpenPET" geometry with shifting detector rings | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yamaya, Taiga
× Yamaya, Taiga× Inaniwa, Taku× Mori, Shinichiro× Furukawa, Takuji× Minohara, Shinichi× Yoshida, Eiji× Nishikido, Fumihiko× Shibuya, Kengo× Inadama, Naoko× Murayama, Hideo× 山谷 泰賀× 稲庭 拓× 森 慎一郎× 古川 卓司× 蓑原 伸一× 吉田 英治× 錦戸 文彦× 澁谷 憲悟× 稲玉 直子× 村山 秀雄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have proposed a new "OpenPET" geometry consisting of two detector rings of axial length W each separated by a gap G. For obtaining an axially continuous field of view (FOV) of 2W ? G, the maximum limit for G must be W. However, two valleys of sensitivity appear on both sides of the gap. Setting a more limited range for the gap as GW, which is desirable for filling in the sensitivity valleys, results in not only a shortened gap, but also a shortened axial FOV. In this paper, we propose an alternative method for improving the uniformity of sensitivity by shifting two detector rings axially closer or further apart at the same velocity to each other. In addition, image reconstruction of the OpenPET is an incomplete problem, and low-frequency components are missing in the gap. Therefore, the proposed method is also expected to improve the conditions for the inverse problem. We simulated an OpenPET scanner which measures events simultaneously by shifting the detector rings. The results showed that the right and left peaks of the sensitivity approach each other upon shifting of the detector rings, and these valleys of sensitivity are effectively recovered. The results also showed that distortion, which is observed for objects containing low-frequency components, is reduced. Larger detector shifts allow a more uniform axial distribution of sensitivity and a higher image quality, but at the cost of a smaller minimum gap. Therefore, an appropriate detector-shifting pattern should be determined based on the desired scanner application. |
|||||
書誌情報 |
Radiological Physics and Technology 巻 2, 号 1, p. 62-69, 発行日 2008-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1865-0333 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12194-008-0046-x |