Inhibition of potential lethal damage repair and related gene expression after carbon-ion beam irradiation to human lung cancer grown in nude mice
https://repo.qst.go.jp/records/45445
https://repo.qst.go.jp/records/4544528066de5-188c-4579-bfc6-0b7cc8a2fdc4
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-03-17 | |||||
タイトル | ||||||
タイトル | Inhibition of potential lethal damage repair and related gene expression after carbon-ion beam irradiation to human lung cancer grown in nude mice | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yashiro, Tomoyasu
× Yashiro, Tomoyasu× Saegusa, Kumiko× Imai, Takashi× Fujisawa, Takehiko× Miyamoto, Tadaaki× 矢代 智康× 三枝 公美子× 今井 高志× 藤澤 武彦× 宮本 忠昭 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Using cultured and nude mouse tumor cells (IA) derived from a human lung cancer, we previously demonstrated their radiosensitivity by focusing attention on the dynamics of tumor clonogens and the early and rapid survival recovery (potential lethal damage repair: PLD repair) occurring after X-ray irradiation. To the authors knowledge, this is the first study demonstrating gene expression in association with PLD repair after carbon-ion beam or X-ray irradiation to cancer cells. In this study we tried to detect the mechanism of DNA damage and repair of the clonogens after X-ray or carbon-ion beam irradiation. At first, colony assay method was performed after irradiation of 12 Gy of X-ray or 5 Gy of carbon-ion beam to compare the time dependent cell survival of the IA cells after each irradiation pass. Second, to search the genes causing PLD repair after irradiation of X-ray or carbon-ion beam, we evaluated gene expressions by using semi-quantitative RT-PCR with the selected 34 genes reportedly related to DNA repair. The intervals from the irradiation were 0, 6, 12 and 24hr for colony assay method, and 0, 3, 18hr for RT-PCR method. From the result of survival assay, PLD repair was not significantly observed in carbon-ion beam as compared to X-ray. The results of RT-PCR were as follows. The gene showing significantly higher expressions after X-ray irradiation than after carbon-ion beam irradiation was PCNA. The genes showing significantly lower expressions after X-ray irradiation rather than after carbon-ion beam irradiation were RAD50, BRCA1, MRE11A, XRCC3, CHEK1, MLH1, CCNB1, CCNB2 and LIG4. We think PCNA among them could be a most hopeful candidate gene for PLD repair. | |||||
書誌情報 |
Journal of Radiation Research 巻 48, 号 5, p. 377-383, 発行日 2007-08 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0449-3060 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1269/jrr.07029 |