Kitagawa, Atsushi
× Kitagawa, Atsushi× Fujita, Takashi× Fukumura, Akifumi× Furukawa, Takuji× Inaniwa, Taku× Iwata, Yoshiyuki× Kanai, Tatsuaki× Kanazawa, Mitsutaka× Kanematsu, Nobuyuki× Kase, Yuuki× Komori, Masataka× Matsufuji, Naruhiro× Minohara, Shinichi× Mizuno, Hideyuki× Murakami, Takeshi× Muramatsu, Masayuki× Noda, Kouji× Ohno, Yumiko× Satou, Shinji× Satou, Yukio× Takada, Eiichi× Torikai, Kota× Torikoshi, Masami× Yamada, Satoru× Yonai, Shunsuke× 北川 敦志× 藤田 敬× 福村 明史× 古川 卓司× 稲庭 拓× 岩田 佳之× 金井 達明× 金澤 光隆× 兼松 伸幸× 加瀬 優紀× 小森 雅孝× 松藤 成弘× 蓑原 伸一× 水野 秀之× 村上 健× 村松 正幸× 野田 耕司× 大野 由美子× 佐藤 眞二× 佐藤 幸夫× 高田 栄一× 鳥飼 幸太× 取越 正己× 山田 聰× 米内 俊祐 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Over 3000 cancer patients have already been treated with 140- to 400-MeV/n carbon beams produced by the heavy ion medical accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences (NIRS) since 1994. These clinical results have clearly verified the advantages of carbon ions. Based on our experience at HIMAC, a hospital-specific facility optimized for carbon-ion therapy has been designed. The prototype developments of an electron cyclotron resonance (ECR) ion source, a radio frequency quadruple (RFQ) linac, an inter digital H (IH) linac, an acceleration system of synchrotron, a beam-delivery system and other key-technology parts have been successfully finished. Thus, in co-operation with NIRS, Gunma University has been constructing a carbon-therapy facility since April, 2006. If the present clinical results are to be improved, it is necessary to create a more accurate dose distribution on tumors without an undesired dose being deposited in normal tissue. Beam-scanning methods with respiration-gated irradiation are especially important to treat a cancer tumor located in the trunk of a patient. | |||||