Optimal scan time of oxygen-15-labeled gas inhalation autoradiographic method for measurement of cerebral oxygen extraction fraction and cerebral oxygen metabolic rate

https://repo.qst.go.jp/records/45432
https://repo.qst.go.jp/records/45432
92963421-38a9-4073-8bba-c3d649665809
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-03-04
タイトル
タイトル Optimal scan time of oxygen-15-labeled gas inhalation autoradiographic method for measurement of cerebral oxygen extraction fraction and cerebral oxygen metabolic rate
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Shidahara, Miho

× Shidahara, Miho

WEKO 451324

Shidahara, Miho

Search repository
Watabe, Hiroshi

× Watabe, Hiroshi

WEKO 451325

Watabe, Hiroshi

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 451326

Ito, Hiroshi

Search repository
Iida, Hidehiro

× Iida, Hidehiro

WEKO 451327

Iida, Hidehiro

Search repository
et.al

× et.al

WEKO 451328

et.al

Search repository
志田原 美保

× 志田原 美保

WEKO 451329

en 志田原 美保

Search repository
渡部 浩司

× 渡部 浩司

WEKO 451330

en 渡部 浩司

Search repository
伊藤 浩

× 伊藤 浩

WEKO 451331

en 伊藤 浩

Search repository
飯田 秀博

× 飯田 秀博

WEKO 451332

en 飯田 秀博

Search repository
抄録
内容記述タイプ Abstract
内容記述 OBJECTIVE: Regional cerebral blood flow (CBF), cerebral blood volume, oxygen extraction fraction (OEF), and cerebral metabolic rate of oxygen (CMRO2) can be estimated from C15O, H(2)15O, and 15O2 tracers and positron emission tomography (PET) using an autoradiographic (ARG) method. Our objective in this study was to optimize the scan time for 15O2 gas study for accurate estimation of OEF and CMRO2.
\nMETHODS: We evaluated statistical noise in OEF by varying the scan time and error caused by the tissue heterogeneity in estimated OEF and CMRO2 using computer simulations. The characteristics of statistical noise were investigated by signal-to-noise (S/N) ratio from repeated tissue time activity curves with noise, which were generated using measured averaged arterial input function and assuming CBF=20, 50, and 80 (ml/100 g per minute). Error caused by tissue heterogeneity was also investigated by estimated OEF and CMRO2 from tissue time activity curve with mixture of gray and white matter varying fraction of mixture. In the simulations, three conditions were assumed (i) CBF in gray and white matter (CBFg and CBFw) was 80 and 20, OEF in gray and white matter (Eg and Ew) was 0.4 and 0.3, (ii) CBFg and CBFw decreased by 50%, and Eg and Ew increased by 50% when compared with conditions (i) and (iii). CBFg and CBFw decreased by 80%, and Eg and Ew increased by 50% when compared with condition (i).
\nRESULTS: The longer scan time produced the better S/N ratio of estimated OEF value from three CBF values (20, 50, and 80). Errors of estimated OEF for three conditions owing to tissue heterogeneity decreased, as scan time took longer. Meanwhile in the case of CMRO2, 3 min of scan time was desirable.
\nCONCLUSIONS: The optimal scan time of 15O2 inhalation study with the ARG method was concluded to be 3 min from taking into account for maintaining the S/N ratio and the quantification of accurate OEF and CMRO2.
書誌情報 Annals of Nuclear Medicine

巻 22, 号 8, p. 667-675, 発行日 2008-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
DOI
識別子タイプ DOI
関連識別子 10.1007/s12149-008-0157-9
戻る
0
views
See details
Views