  1. 原著論文

Evaluatuion of w values for carbon beams in air, using a graphite calorimeter

https://repo.qst.go.jp/records/45427
https://repo.qst.go.jp/records/45427
bb188a63-6279-4b4f-a2ed-041c4c3d0fde
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-02-20
タイトル
タイトル Evaluatuion of w values for carbon beams in air, using a graphite calorimeter
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sakama, Makoto

× Sakama, Makoto

WEKO 451284

Sakama, Makoto

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 451285

Kanai, Tatsuaki

Search repository
Fukumura, Akifumi

× Fukumura, Akifumi

WEKO 451286

Fukumura, Akifumi

Search repository
Abe, Kyoko

× Abe, Kyoko

WEKO 451287

Abe, Kyoko

Search repository
坂間 誠

× 坂間 誠

WEKO 451288

en 坂間 誠

Search repository
金井 達明

× 金井 達明

WEKO 451289

en 金井 達明

Search repository
福村 明史

× 福村 明史

WEKO 451290

en 福村 明史

Search repository
坂間 杏子

× 坂間 杏子

WEKO 451291

en 坂間 杏子

Search repository
抄録
内容記述タイプ Abstract
内容記述 Abstract. Despite recent progress in carbon therapy, accurate values for physical data such as the w value in air or stopping power ratios for ionization chamber dosimetry have not been obtained. The absorbed dose to graphite obtained with the graphite calorimeter was compared with that obtained using the ionization chambers following the IAEA protocol in order to evaluate the w values in air for mono-energetic carbon beams of 135, 290, 400 and 430 MeV/n. Two cylindrical chambers (PTW type 30001 and PTW type 30011, Farmer) and two plane-parallel chambers (PTW type 23343, Markus and PTW type 34001, Roos) calibrated by the absorbed dose to graphite and exposure to the 60Co photon beam were used. The comparisons to our calorimeter measurements revealed that, using the ionization chambers, the absorbed dose to graphite comes out low by 2–6% in this experimental energy range and with these chamber types and calibration methods. In the therapeutic energy range, the w values in air for carbon beams indicated a slight energy dependence; we, however, assumed these values to be constant for practical use because of the large uncertainty and unknown perturbation factors of the ionization chambers. The w values in air of the carbon beams were evaluated to be 35.72 J C−1
1.5% in the energy range used in this study. This value is 3.5% larger than that recommended by the IAEA TRS 398 for heavy-ion beams. Using this evaluated result, the absorbed dose to water in the carbon beams would be increased by the same amount.
書誌情報 Physics in Medicine and Biology

巻 54, 号 5, p. 1111-1130, 発行日 2009-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
識別子タイプ DOI
関連識別子 10.1088/0031-9155/54/002
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:03:51.411953
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3