Specification of Carbon Ion Dose at the National Institute of Radiological Sciences(NIRS).

https://repo.qst.go.jp/records/45414
https://repo.qst.go.jp/records/45414
9fff6d06-2ecf-4a0a-b4f9-9e0e2512f534
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-02-05
タイトル
タイトル Specification of Carbon Ion Dose at the National Institute of Radiological Sciences(NIRS).
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 451077

Matsufuji, Naruhiro

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 451078

Kanai, Tatsuaki

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 451079

Kanematsu, Nobuyuki

Search repository
Miyamoto, Tadaaki

× Miyamoto, Tadaaki

WEKO 451080

Miyamoto, Tadaaki

Search repository
Baba, Masayuki

× Baba, Masayuki

WEKO 451081

Baba, Masayuki

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 451082

Kamada, Tadashi

Search repository
Katou, Hirotoshi

× Katou, Hirotoshi

WEKO 451083

Katou, Hirotoshi

Search repository
Yamada, Shigeru

× Yamada, Shigeru

WEKO 451084

Yamada, Shigeru

Search repository
Mizoe, Junetsu

× Mizoe, Junetsu

WEKO 451085

Mizoe, Junetsu

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 451086

Tsujii, Hirohiko

Search repository
松藤 成弘

× 松藤 成弘

WEKO 451087

en 松藤 成弘

Search repository
金井 達明

× 金井 達明

WEKO 451088

en 金井 達明

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 451089

en 兼松 伸幸

Search repository
宮本 忠昭

× 宮本 忠昭

WEKO 451090

en 宮本 忠昭

Search repository
馬場 雅行

× 馬場 雅行

WEKO 451091

en 馬場 雅行

Search repository
鎌田 正

× 鎌田 正

WEKO 451092

en 鎌田 正

Search repository
加藤 博敏

× 加藤 博敏

WEKO 451093

en 加藤 博敏

Search repository
山田 滋

× 山田 滋

WEKO 451094

en 山田 滋

Search repository
溝江 純悦

× 溝江 純悦

WEKO 451095

en 溝江 純悦

Search repository
辻井 博彦

× 辻井 博彦

WEKO 451096

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 The clinical dose distributions of therapeutic carbon beams, currently used at NIRS HIMAC, are based on in-vitro Human Salivary Gland (HSG) cell survival response and clinical experience from fast neutron radiotherapy. Moderate radiosensitivity of HSG cells is expected to be a typical response of tumours to carbon beams. At first, the biological dose distribution is designed so as to cause a flat biological effect on HSG cells in the spread-out Bragg peak (SOBP) region. Then, the entire biological dose distribution is evenly raised in order to attain a RBE (relative biological effectiveness) = 3.0 at a depth where dose-averaged LET (linear energy transfer) is 80 keV/mum. At that point, biological experiments have shown that carbon ions can be expected to have a biological effect identical to fast neutrons, which showed a clinical RBE of 3.0 for fast neutron radiotherapy at NIRS. The resulting clinical dose distribution in this approximation is not dependent on dose level, tumour type or fractionation scheme and thus reduces the unknown parameters in the analysis of the clinical results. The width SOBP and the clinical / physical dose at the center of SOBP specify the dose distribution. The clinical results analysed in terms of TCP were found to show good agreement with the expected RBE value at higher TCP levels. The TCP analysis method was applied for the prospective dose estimation of hypofractionation.
書誌情報 Journal of Radiation Research

巻 48, 号 Suppl A, p. A81-A86, 発行日 2007-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:04:00.845466
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3