Effective Doses in Four-dimensional Computed Tomography For Lung Radiotherapy Planning

https://repo.qst.go.jp/records/45411
https://repo.qst.go.jp/records/45411
615c2bb7-a232-4421-92ee-c2a3955b7efb
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2009-02-02
タイトル
タイトル Effective Doses in Four-dimensional Computed Tomography For Lung Radiotherapy Planning
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 451059

Mori, Shinichiro

Search repository
Ko, Susumu

× Ko, Susumu

WEKO 451060

Ko, Susumu

Search repository
Ishii, Takayoshi

× Ishii, Takayoshi

WEKO 451061

Ishii, Takayoshi

Search repository
Nishizawa, Kanae

× Nishizawa, Kanae

WEKO 451062

Nishizawa, Kanae

Search repository
森 慎一郎

× 森 慎一郎

WEKO 451063

en 森 慎一郎

Search repository
幸 進

× 幸 進

WEKO 451064

en 幸 進

Search repository
石居 隆義

× 石居 隆義

WEKO 451065

en 石居 隆義

Search repository
西澤 かな枝

× 西澤 かな枝

WEKO 451066

en 西澤 かな枝

Search repository
抄録
内容記述タイプ Abstract
内容記述 The recent broad adoption of four-dimensional CT (4DCT) scanning in radiotherapy has allowed the accurate determination of the target volume of tumors by minimizing image degradation due to respiratory motion. Although the radiation exposure of the treatment beam is significantly greater than that of CT scans used for treatment planning, it is important to recognize and optimize the radiation exposure in 4DCT from the radiological protection point of view. Here, radiation exposure in 4DCT was measured with a 16 multi-detector CT. Organ doses were measured using TLD chips inserted at respective anatomical sites of an anthropomorphic phantom. Results were compared with those with the helical CT scan mode. The effective dose measured for 4DCT was 24.7 mSv, approximately four times higher than that for helical CT. However, the increase in treatment accuracy afforded by 4DCT means its use in radiotherapy is inevitable. The patient exposure in the 4DCT could be of value by clarifying the advantage of the treatment planning using 4DCT
書誌情報 Medical Dosimetry

巻 34, 号 1, p. 87-90, 発行日 2009-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0958-3947
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:04:02.887884
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3