ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Track detector of CR-39-DAP-copolymer with variable threshold to detect trans-iron nuclei in galactic cosmic rays

https://repo.qst.go.jp/records/45384
https://repo.qst.go.jp/records/45384
a7ed9279-d4a3-46da-bf91-52b4b1e40f2d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-01-05
タイトル
タイトル Track detector of CR-39-DAP-copolymer with variable threshold to detect trans-iron nuclei in galactic cosmic rays
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kodaira, Satoshi

× Kodaira, Satoshi

WEKO 450829

Kodaira, Satoshi

Search repository
Doke, Tadayoshi

× Doke, Tadayoshi

WEKO 450830

Doke, Tadayoshi

Search repository
Hasebe, Nobuyuki

× Hasebe, Nobuyuki

WEKO 450831

Hasebe, Nobuyuki

Search repository
Ogura, Kouichi

× Ogura, Kouichi

WEKO 450832

Ogura, Kouichi

Search repository
Yasuda, Nakahiro

× Yasuda, Nakahiro

WEKO 450833

Yasuda, Nakahiro

Search repository
Tsuruta, Takao

× Tsuruta, Takao

WEKO 450834

Tsuruta, Takao

Search repository
et.al

× et.al

WEKO 450835

et.al

Search repository
小平 聡

× 小平 聡

WEKO 450836

en 小平 聡

Search repository
道家 忠義

× 道家 忠義

WEKO 450837

en 道家 忠義

Search repository
安田 仲宏

× 安田 仲宏

WEKO 450838

en 安田 仲宏

Search repository
鶴田 隆雄

× 鶴田 隆雄

WEKO 450839

en 鶴田 隆雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 Observation of trans-iron nuclei in galactic cosmic rays (Z>30) requires a high performance cosmic ray detector telescope with a large exposure area because of their extremely low fluxes. A solid-state track detector such as CR-39 has the advantage of easy extension of exposure area, but it is necessary to raise the Z/beta detection threshold in order to suppress background tracks produced by galactic cosmic rays with Z/beta<30. The track registration sensitivity and detection threshold for heavy ions with various Z*/beta were verified by using track detectors of copolymers of CR-39 and DAP (diallyl phthalate) with various DAP concentration. We found that it is possible to control the Z*/beta detection
threshold of copolymers by changing DAP concentration. In order to detect heavy ions with Z*/beta > 30, the optimum DAP concentration was
found to be approximately 50%.
書誌情報 Radiation Measurements

巻 43, 号 Suppl.1, p. S52-S55, 発行日 2008-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 1350-4487
戻る
0
views
See details
Views