Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters

https://repo.qst.go.jp/records/45338
https://repo.qst.go.jp/records/45338
6b31ae67-41a3-43dd-b5a4-58eb7df90b0d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-12-04
タイトル
タイトル Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Moritake, Takashi

× Moritake, Takashi

WEKO 450402

Moritake, Takashi

Search repository
Matsumaru, Yuji

× Matsumaru, Yuji

WEKO 450403

Matsumaru, Yuji

Search repository
Takigawa, Tomoji

× Takigawa, Tomoji

WEKO 450404

Takigawa, Tomoji

Search repository
Nishizawa, Kanae

× Nishizawa, Kanae

WEKO 450405

Nishizawa, Kanae

Search repository
Matsumura, Akira

× Matsumura, Akira

WEKO 450406

Matsumura, Akira

Search repository
Tsuboi, Koji

× Tsuboi, Koji

WEKO 450407

Tsuboi, Koji

Search repository
盛武 敬

× 盛武 敬

WEKO 450408

en 盛武 敬

Search repository
西澤 かな枝

× 西澤 かな枝

WEKO 450409

en 西澤 かな枝

Search repository
坪井 康次

× 坪井 康次

WEKO 450410

en 坪井 康次

Search repository
抄録
内容記述タイプ Abstract
内容記述 BACKGROUND AND PURPOSE: Although radiation skin injuries associated with interventional radiology have been known as a critical issue, there are few reports mentioning direct measurement of the entrance skin dose (ESD). Thus, the purpose of this study was to clarify the regional distributions of ESDs in neurointervention.
\nMATERIALS AND METHODS: Using photoluminescence glass dosimeters (PLDs), we measured the ESDs in 32 patients with a median age of 61.5 years. Angiographic parameters, including exposure time, dose-area product (DAP), and the number of digital subtraction angiography (DSA) studies and frames, were recorded. The ESDs of operators were analyzed by the same method.
\nRESULTS: The maximum ESD of 28 therapeutic procedures was 1.8 +/- 1.3 Gy. Although the averaged ESD on the right temporo-occipital region was higher than that in other regions, disease-specific patterns were not observed. Statistically positive correlations were found between the maximum ESD and exposure time (r = 0.5283, P = .005), DAP (r = 0.7917, P < .001), the number of DSA studies (r = 0.5636, P = .002), and the number of DSA frames (r = 0.8583, P < .001). As for operators, ESDs to the left upper extremity were significantly higher than those to other regions. However, most of the ESDs were <0.2 mGy. Lead protective garments reduced the exposure doses to approximately one half to one tenth.
\nCONCLUSION: It was shown that the regional ESD could be measured by applying the PLD. This method should contribute to reducing the dose accumulation in patients as well as in operators.
書誌情報 American Journal of Neuroradiology

巻 29, 号 10, p. 1910-1917, 発行日 2008-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 0195-6108
DOI
識別子タイプ DOI
関連識別子 10.3174/ajnr.a1235
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:04:54.013468
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3