ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Comparative study of dose distribution between carbon ion radiotherapy and photon radiotherapy for head and neck tumor

https://repo.qst.go.jp/records/45320
https://repo.qst.go.jp/records/45320
08470549-f792-4843-b577-5471bea8f3cf
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-11-18
タイトル
タイトル Comparative study of dose distribution between carbon ion radiotherapy and photon radiotherapy for head and neck tumor
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Islam, Amirul

× Islam, Amirul

WEKO 450228

Islam, Amirul

Search repository
Yanagi, Takeshi

× Yanagi, Takeshi

WEKO 450229

Yanagi, Takeshi

Search repository
Mizoe, Junetsu

× Mizoe, Junetsu

WEKO 450230

Mizoe, Junetsu

Search repository
Mizuno, Hideyuki

× Mizuno, Hideyuki

WEKO 450231

Mizuno, Hideyuki

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 450232

Tsujii, Hirohiko

Search repository
柳 剛

× 柳 剛

WEKO 450233

en 柳 剛

Search repository
溝江 純悦

× 溝江 純悦

WEKO 450234

en 溝江 純悦

Search repository
水野 秀之

× 水野 秀之

WEKO 450235

en 水野 秀之

Search repository
辻井 博彦

× 辻井 博彦

WEKO 450236

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: A comparative treatment planning study has been performed between carbon ion radiotherapy (CIRT) and photon radiotherapy [three-dimensional conformal radiotherapy (3D-CRT) and intensitymodulated radiotherapy (IMRT)] to assess the potential improvements and limitations that could result for locally advanced, nonresectable head and neck tumors.
Materials and methods: Seven patients, originally treated with CIRT, were randomly selected for the comparative study. The evaluations analyzed using dose-volume histogram parameters, conformity index, inhomogeneity coefficient, and dose to the organs at risk (OARs).
Results: The mean conformity index was 1.46,1.43,and 1.22 for 3D-CRT, IMRT,and CIRT, respectively. The mean inhomogeneity coefficient was 0.05,0.07,and 0.02 for 3D-CRT, IMRT,and CIRT respectively. Photon plans resulted in greater volumes of normal tissues at 10% to 95% isodose levels compared with the corresponding carbon ion plans where the volumes increased by a factor of 1.2 to 2.7 for 3D-CRT and 1.2 to 2.0 for IMRT.
Conclusion: CIRT has the potential to improve the target dose conformity inhomogeneity coefficient, and OAR sparing when compared with 3D-CRT and IMRT. Compared with 3D-CRT, normal tissue exposure was reduced mainly in the mid-to low-isodose levels using IMRT. Additional improvement was obtained using CIRT.
書誌情報 Radiation Medicine

巻 26, 号 7, p. 415-421, 発行日 2008-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 0288-2043
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:05:06.757289
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3