ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Development of treatment planning for scanning irradiation at HIMAC

https://repo.qst.go.jp/records/45291
https://repo.qst.go.jp/records/45291
9957339c-ac50-459b-867b-70c46e89edd5
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-10-08
タイトル
タイトル Development of treatment planning for scanning irradiation at HIMAC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, Taku

× Inaniwa, Taku

WEKO 449923

Inaniwa, Taku

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 449924

Furukawa, Takuji

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 449925

Satou, Shinji

Search repository
Tomitani, Takehiro

× Tomitani, Takehiro

WEKO 449926

Tomitani, Takehiro

Search repository
Minohara, Shinichi

× Minohara, Shinichi

WEKO 449927

Minohara, Shinichi

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 449928

Noda, Kouji

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 449929

Kanai, Tatsuaki

Search repository
et.al

× et.al

WEKO 449930

et.al

Search repository
稲庭 拓

× 稲庭 拓

WEKO 449931

en 稲庭 拓

Search repository
古川 卓司

× 古川 卓司

WEKO 449932

en 古川 卓司

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 449933

en 佐藤 眞二

Search repository
富谷 武浩

× 富谷 武浩

WEKO 449934

en 富谷 武浩

Search repository
蓑原 伸一

× 蓑原 伸一

WEKO 449935

en 蓑原 伸一

Search repository
野田 耕司

× 野田 耕司

WEKO 449936

en 野田 耕司

Search repository
金井 達明

× 金井 達明

WEKO 449937

en 金井 達明

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to utilize an intensity-controlled raster scan method at the new treatment facility in HIMAC, we have developed, as a first step, a research version of a treatment planning tool. In this tool, treatment plans are produced according to the following steps: (a) import a planned target volume (PTV) delineated on a CT data set, (b) determine the primary treatment parameters, (c) convert the PTV in the CT system to the one in the water equivalent system, (d) choose beam positions within the PTV, (e) optimize the scan trajectory, (f) determine the particle numbers for each pencil beam and (g) produce the beam steering file. As an example, a treatment plan was produced for the data of a patient treated at HIMAC in this paper. The reliability of the tool was confirmed with irradiation experiments according to the obtained beam steering file.
書誌情報 Nuclear Instruments & Methods in Physics Research Section B

巻 266, 号 10, p. 2194-2198, 発行日 2008-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-583X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nimb.2008.02.070
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:05:28.179959
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3