タイトル Multiply charged carbon-ion production for medical application
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kitagawa, Atsushi

× Kitagawa, Atsushi

WEKO 449887

Kitagawa, Atsushi

Search repository
Muramatsu, Masayuki

× Muramatsu, Masayuki

WEKO 449888

Muramatsu, Masayuki

Search repository
Biri, Sandor

× Biri, Sandor

WEKO 449889

Biri, Sandor

Search repository
Drentje, Arne

× Drentje, Arne

WEKO 449890

Drentje, Arne

Search repository
et.al

× et.al

WEKO 449891

et.al

Search repository
北川 敦志

× 北川 敦志

WEKO 449892

en 北川 敦志

Search repository
村松 正幸

× 村松 正幸

WEKO 449893

en 村松 正幸

Search repository
Sandor Biri

× Sandor Biri

WEKO 449894

en Sandor Biri

Search repository
Arne Drentje

× Arne Drentje

WEKO 449895

en Arne Drentje

Search repository
抄録
内容記述タイプ Abstract
内容記述 Over 3000 cancer patients have already been treated by the heavy-ion medical accelerator in Chiba at the National Institute of Radiological Sciences since 1994. The clinical results have clearly verified the effectiveness and safety of heavy-ion radiotherapy. The most important result has been to establish that the carbon ion is one of the most effective radiations for radiotherapy. The ion source is required to realize a stable beam with the same conditions for daily operation. However, the deposition of carbon ions on the wall of the plasma chamber is normally unavoidable. This causes an "anti-wall-coating effect," i.e., a decreasing of the beam, especially for the higher charge-state ions due to the surface material of the wall. The ion source must be required to produce a sufficiently intense beam under the bad condition. Other problems were solved by improvements and maintenance, and thus we obtained enough reproducibility and stability along with decreased failures. We summarize our over 13 years of experience, and show the scope for further developments.
書誌情報 Review of Scientific Instruments

巻 79, 号 2, p. 02C303-1-02C303-3, 発行日 2008-02
ISSN
収録物識別子タイプ ISSN
収録物識別子 0034-6748
DOI
識別子タイプ DOI
関連識別子 10.1063/1.2832361
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:05:30.237376
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3