Development of gas pulsing system for electron cyclotron resonance ion source

https://repo.qst.go.jp/records/45286
https://repo.qst.go.jp/records/45286
70276e99-c692-4be3-a5ce-c10edf1c24db
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-10-08
タイトル
タイトル Development of gas pulsing system for electron cyclotron resonance ion source
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Houjou, Satoru

× Houjou, Satoru

WEKO 449866

Houjou, Satoru

Search repository
Honma, Toshihiro

× Honma, Toshihiro

WEKO 449867

Honma, Toshihiro

Search repository
Muramatsu, Masayuki

× Muramatsu, Masayuki

WEKO 449868

Muramatsu, Masayuki

Search repository
Sakamoto, Yukio

× Sakamoto, Yukio

WEKO 449869

Sakamoto, Yukio

Search repository
Sugiura, Akinori

× Sugiura, Akinori

WEKO 449870

Sugiura, Akinori

Search repository
北條 悟

× 北條 悟

WEKO 449871

en 北條 悟

Search repository
本間 壽廣

× 本間 壽廣

WEKO 449872

en 本間 壽廣

Search repository
村松 正幸

× 村松 正幸

WEKO 449873

en 村松 正幸

Search repository
坂本 幸雄

× 坂本 幸雄

WEKO 449874

en 坂本 幸雄

Search repository
杉浦 彰則

× 杉浦 彰則

WEKO 449875

en 杉浦 彰則

Search repository
抄録
内容記述タイプ Abstract
内容記述 A gas-pulsing system for an electron cyclotron resonance ion source with all permanent magnets (Kei2 source) at NIRS has been developed and tested. The system consists of a small vessel (30 ml) to reserve CH4 gas and two fast solenoid valves that are installed at both sides of the vessel. They are connected to each other and to the Kei2 source by using a stainless-steel pipe (4 mm inner diameter), where the length of the pipe from the valve to the source is 60 cm and the conductance is 1.2 l / s. From the results of the test, almost 300 e microA for a pulsed 12C4+ beam was obtained at a Faraday cup in an extraction-beam channel with a pressure range of 4000 Pa in the vessel. At this time, the valve has an open time of 10 ms and the delay time between the valve open time and the application of microwave power is 100 ms. In experiments, the conversion efficiency for input CH4 molecules to the quantity of extracted 12C4+ ions in one beam pulse was found to be around 3% and the ratio of the total amount of the gas requirement was only 10% compared with the case of continuous gas provided in 3.3 s of repetition in HIMAC.
書誌情報 Review of Scientific Instruments

巻 79, 号 2, p. 02A306-1-02A306-3, 発行日 2008-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0034-6748
DOI
識別子タイプ DOI
関連識別子 10.1063/1.2805233
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:05:31.649465
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3