Calculation of Dose Contributions of Electron and Charged Heavy Particles inside Phantoms Irradiated by Monoenergetic Neutron

https://repo.qst.go.jp/records/45281
https://repo.qst.go.jp/records/45281
1606661a-24bd-4da4-8c69-8a9db6bc59f6
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-10-06
タイトル
タイトル Calculation of Dose Contributions of Electron and Charged Heavy Particles inside Phantoms Irradiated by Monoenergetic Neutron
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Satoh, Daiki

× Satoh, Daiki

WEKO 449823

Satoh, Daiki

Search repository
Endo, Akira

× Endo, Akira

WEKO 449824

Endo, Akira

Search repository
Ohmachi, Yasushi

× Ohmachi, Yasushi

WEKO 449825

Ohmachi, Yasushi

Search repository
Miyahara, Nobuyuki

× Miyahara, Nobuyuki

WEKO 449826

Miyahara, Nobuyuki

Search repository
et.al

× et.al

WEKO 449827

et.al

Search repository
遠藤 章

× 遠藤 章

WEKO 449828

en 遠藤 章

Search repository
大町 康

× 大町 康

WEKO 449829

en 大町 康

Search repository
宮原 信幸

× 宮原 信幸

WEKO 449830

en 宮原 信幸

Search repository
抄録
内容記述タイプ Abstract
内容記述 The radiation-transport code PHITS with an event generator mode has been applied to analyze energy depositions of electrons and charged heavy particles in two spherical phantoms and a voxel-based mouse phantom upon neutron irradiation. The calculations using the spherical phantoms quantitatively clarified the type and energy of charged particles which are released through interactions of neutrons with the phantom elements and contribute to the radiation dose. The relative contribution of electrons increased with an increase in the size of the phantom and with a decrease in the energy of the incident neutrons. Calculations with the voxel-based mouse phantom for 2.0-MeV neutron irradiation revealed that the doses to different locations inside the body are uniform, and that the energy is mainly deposited by recoil protons. The present study has demonstrated that analysis using PHITS can yield dose distributions that are accurate enough for RBE evaluation.
書誌情報 Journal of Radiation Research

巻 49, 号 5, p. 503-508, 発行日 2008-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
戻る
0
views
See details
Views