Isotope dilution sector-field inductively coupled plasma mass spectrometry combined with extraction chromatography for rapid determination of 241Am in marine sediment samples: a case study in Sagami bay, Japan

https://repo.qst.go.jp/records/45224
https://repo.qst.go.jp/records/45224
e3268638-8990-4eb1-b20e-0e560648d5a6
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-07-16
タイトル
タイトル Isotope dilution sector-field inductively coupled plasma mass spectrometry combined with extraction chromatography for rapid determination of 241Am in marine sediment samples: a case study in Sagami bay, Japan
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zheng, Jian

× Zheng, Jian

WEKO 449200

Zheng, Jian

Search repository
Yamada, Masatoshi

× Yamada, Masatoshi

WEKO 449201

Yamada, Masatoshi

Search repository
鄭 建

× 鄭 建

WEKO 449202

en 鄭 建

Search repository
山田 正俊

× 山田 正俊

WEKO 449203

en 山田 正俊

Search repository
抄録
内容記述タイプ Abstract
内容記述 241Am is a useful tracer in understanding biogeochemical processes in the marine environment. 241Am also poses a potential radiation threat against human health due to the continuous increase of its concentration in the global environment. We report a rapid analytical method for 241Am in marine sediments using isotope dilution sector-field inductively coupled plasma mass spectrometry (SF-ICP-MS) combined with a high-efficiency sample introduction system (APEX-Q). A selective CaF2 co-precipitation procedure followed by TRU extraction chromatography was employed to effectively remove the major sediment matrix and to pre-concentrate 241Am. We achieved an extremely low detection limit of 0.32 fg/g or 0.041 mBq/g (for 1 gram sediment), which is better than that of alpha spectrometry, and it allowed the accurate determination of 241Am in low-level marine sediment samples. The accuracy and precision of the developed analytical method was evaluated using a laboratory prepared Am isotope standard solution and Ocean Sediment reference material (IAEA-368) and the results were satisfactory. For sediment samples, overall, chemical recoveries varied from 60 - 90 %. The developed method was applied to the study of 241Am depth distribution in Sagami Bay, Japan, in which we observed different depth profiles between 241Am activity and 239+240Pu activity.
書誌情報 Journal of Oceanography

巻 64, 号 4, p. 541-550, 発行日 2008-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 0916-8370
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:06:16.391986
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3