ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Successive positron emission tomography measurement of cerebral blood flow and neuroreceptors in the human brain: an 11C-SA4503 study

https://repo.qst.go.jp/records/45219
https://repo.qst.go.jp/records/45219
8d3d36c7-9e83-441b-934a-176da0a760aa
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-07-08
タイトル
タイトル Successive positron emission tomography measurement of cerebral blood flow and neuroreceptors in the human brain: an 11C-SA4503 study
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ishiwata, Kiichi

× Ishiwata, Kiichi

WEKO 449132

Ishiwata, Kiichi

Search repository
Ishii, Kenji

× Ishii, Kenji

WEKO 449133

Ishii, Kenji

Search repository
Kimura, Yuichi

× Kimura, Yuichi

WEKO 449134

Kimura, Yuichi

Search repository
Kawamura, Kazunori

× Kawamura, Kazunori

WEKO 449135

Kawamura, Kazunori

Search repository
Oda, Keiichi

× Oda, Keiichi

WEKO 449136

Oda, Keiichi

Search repository
Sasaki, Touru

× Sasaki, Touru

WEKO 449137

Sasaki, Touru

Search repository
Sakata, Muneyuki

× Sakata, Muneyuki

WEKO 449138

Sakata, Muneyuki

Search repository
Senda, Michio

× Senda, Michio

WEKO 449139

Senda, Michio

Search repository
石渡 喜一

× 石渡 喜一

WEKO 449140

en 石渡 喜一

Search repository
石井 賢二

× 石井 賢二

WEKO 449141

en 石井 賢二

Search repository
木村 裕一

× 木村 裕一

WEKO 449142

en 木村 裕一

Search repository
河村 和紀

× 河村 和紀

WEKO 449143

en 河村 和紀

Search repository
織田 圭一

× 織田 圭一

WEKO 449144

en 織田 圭一

Search repository
坂田 宗之

× 坂田 宗之

WEKO 449145

en 坂田 宗之

Search repository
抄録
内容記述タイプ Abstract
内容記述 For evaluating a newly developed radioligand for positron emission tomography (PET), successive measurements of regional cerebral blood flow (rCBF) and the kinetics of the radioligand in the same subject are preferable in the first clinical trial. In this study, we demonstrate an example for the study of (11)C-labeled 1-(3,4-dimethoxyphenethyl)-4-(3-phenylprophyl) piperazine ((11)C-SA4503) for mapping sigma(1) receptors in the human brain. Five healthy male subjects underwent two successive PET scans with (15)O-H(2)O to measure the rCBF and with (11)C-SA4503 (dynamic 60-min scan). The brain kinetics of (11)C-SA4503 was evaluated using the time-activity curve (TAC) of tissue in each of the 11 regions of the brain and the metabolite-corrected TAC of plasma on the basis of a two-tissue compartment fourparameter model. The estimated parameters were four rate constants: K (1), influx from plasma to brain tissue; k (2), efflux from tissue to plasma; k (3), association between tracer and receptors; and k (4), dissociation of tracer-receptor complex, and the binding potential (BP), k (3)/k (4). (11)CSA4503 was distributed all over the brain, and the TACs exhibited an accumulation pattern in all the 11 regions. K (1) of (11)C-SA4503 correlated with rCBF, but the other three rate constant parameters and BP did not. The regional difference in the BP of (11)C-SA4503 is compatible with those of sigma(1) receptors. In conclusion, successive PET measurements of rCBF and the brain kinetics of radioligand-neuroreceptor binding are useful for the first clinical trial of a newly developed radioligand for mapping neuroreceptors, and the protocol is applicable to pathophysiological studies of brain disorders.
書誌情報 Annals of Nuclear Medicine

巻 22, 号 5, p. 411-416, 発行日 2008-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
DOI
識別子タイプ DOI
関連識別子 10.1007/s12149-008-0133-4
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:06:19.826318
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3