ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

A novel multi-collimator using BP-1 glass and an application for X-ray CCDs

https://repo.qst.go.jp/records/45191
https://repo.qst.go.jp/records/45191
02a00692-056e-4a00-b60b-ba51d23e3a10
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-06-11
タイトル
タイトル A novel multi-collimator using BP-1 glass and an application for X-ray CCDs
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hiraga, Junko

× Hiraga, Junko

WEKO 448871

Hiraga, Junko

Search repository
Nakamura, Shogo

× Nakamura, Shogo

WEKO 448872

Nakamura, Shogo

Search repository
Uchida, Yoshihiro

× Uchida, Yoshihiro

WEKO 448873

Uchida, Yoshihiro

Search repository
Kikuchi, Masato

× Kikuchi, Masato

WEKO 448874

Kikuchi, Masato

Search repository
Kurata, Shingo

× Kurata, Shingo

WEKO 448875

Kurata, Shingo

Search repository
Ozaki, Yuichi

× Ozaki, Yuichi

WEKO 448876

Ozaki, Yuichi

Search repository
Kamada, Shintaro

× Kamada, Shintaro

WEKO 448877

Kamada, Shintaro

Search repository
Takashima, Takeshi

× Takashima, Takeshi

WEKO 448878

Takashima, Takeshi

Search repository
Uchihori, Yukio

× Uchihori, Yukio

WEKO 448879

Uchihori, Yukio

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 448880

Kitamura, Hisashi

Search repository
Tawara, Hiroko

× Tawara, Hiroko

WEKO 448881

Tawara, Hiroko

Search repository
内堀 幸夫

× 内堀 幸夫

WEKO 448882

en 内堀 幸夫

Search repository
北村 尚

× 北村 尚

WEKO 448883

en 北村 尚

Search repository
俵 裕子

× 俵 裕子

WEKO 448884

en 俵 裕子

Search repository
抄録
内容記述タイプ Abstract
内容記述 Charge-coupled devices (CCDs) are widely used in X-ray astronomy as a focal plane detector for X-rays up to 10 keV. For future X-ray space missions, thick CCDs are being developed to improve the detection efficiency of high energy X-rays beyond 10 keV. We propose a new method to produce a novel multi-collimator using a barium phosphate glass, BP-1, which was originally developed as a solid state track detector. The BP-1 collimator allows the realization of small through-holes, several hundred nano-meters in radius. We performed the first experiment of this project in which a xenon beam of 80MeV=u was used to irradiate the 1.3 mm-thick-BP-1 glass. After an etching process, we obtained the first prototype BP-1 collimator. There were a large number of tapered pinholes which are randomly distributed and with extremely high aspect ratio. Taking X-ray photographs demonstrated that the first prototype has a capability of fine collimation for X-rays up to 20 keV.
r 2006 Elsevier B.V. All rights reserved.
書誌情報 Nuclear Instruments & Methods in Physics Research Section A

巻 573, 号 1/2, p. 236-239, 発行日 2007-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:06:35.875285
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3