ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Determination of Plutonium isotopes in freshwater lake sediments by sector field ICP-MS after separation using ion-exchange chromatography

https://repo.qst.go.jp/records/45179
https://repo.qst.go.jp/records/45179
ee2a39c9-b473-44e0-b16c-92888ae92361
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-06-10
タイトル
タイトル Determination of Plutonium isotopes in freshwater lake sediments by sector field ICP-MS after separation using ion-exchange chromatography
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Liao, Haiqing

× Liao, Haiqing

WEKO 448733

Liao, Haiqing

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 448734

Zheng, Jian

Search repository
Wu, Fengchang

× Wu, Fengchang

WEKO 448735

Wu, Fengchang

Search repository
Yamada, Masatoshi

× Yamada, Masatoshi

WEKO 448736

Yamada, Masatoshi

Search repository
Tan, Mingguang

× Tan, Mingguang

WEKO 448737

Tan, Mingguang

Search repository
Chen, Jianmin

× Chen, Jianmin

WEKO 448738

Chen, Jianmin

Search repository
Liao Haiqing

× Liao Haiqing

WEKO 448739

en Liao Haiqing

Search repository
鄭 建

× 鄭 建

WEKO 448740

en 鄭 建

Search repository
山田 正俊

× 山田 正俊

WEKO 448741

en 山田 正俊

Search repository
抄録
内容記述タイプ Abstract
内容記述 The determination of Pu isotopes in lake sediments is important for many studies, such as Pu pollution source identification, sediment mixing estimation, erosion evaluation and establishment of deposition chronology in lakes. In this paper, a simple analytical method using sector field ICP-MS combined with two-stage chromatographic separation and purification of Pu was developed based on the optimization and adaptation of the previously published method for marine samples with an emphasis on the study of the elimination of interferences for the analysis of freshwater lake sediments. A strong base anion exchange resin (AG MP-1M) was used to purify Pu isotopes with concentrated HBr as the final eluent for Pu elution. The chemical yields were ca. 64% and the decontamination factor for U was ca. 105. The developed method was validated using a freshwater lake sediment reference material (SRM-4354) and a marine sediment reference material (IAEA-368), and applied to the determination of Pu isotopes in sediment samples of Lake Poyang, East China. For the analysis of certified reference materials, both 239+240Pu activity of 31.6 mBq g-1 and 240Pu/239Pu atom ratio of 0.033 for IAEA-368 were comparable to the certified value and/or literature values. As for SRM-4354, 239+240Pu activity of 3.90 mBq g-1 agreed well with the certified value. However, the mean 240Pu/239Pu atom ratio of 0.144 was lower than those reported by other laboratories. This difference suggested that this material may be isotopically inhomogeneous. 240Pu/239Pu atom ratios of Poyang Lake sediment samples ranged from 0.185 to 0.192 with a mean value of 0.187+/-0.004, indicating that plutonium pollution originated from global fallout.
書誌情報 Applied Radiation and Isotopes

巻 66, 号 8, p. 1138-1145, 発行日 2008-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0969-8043
DOI
識別子タイプ DOI
関連識別子 10.1016/j.apradiso.2008.01.001
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:06:44.303749
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3