MR imaging of the female pelvis at 3 Tesla: Evaluation of image homogeneity using different dielectric pads.

https://repo.qst.go.jp/records/45102
https://repo.qst.go.jp/records/45102
92121747-923b-43cf-983f-ebe16d48d725
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-03-03
タイトル
タイトル MR imaging of the female pelvis at 3 Tesla: Evaluation of image homogeneity using different dielectric pads.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kataoka, Masako

× Kataoka, Masako

WEKO 447878

Kataoka, Masako

Search repository
Isoda, Hiroyoshi

× Isoda, Hiroyoshi

WEKO 447879

Isoda, Hiroyoshi

Search repository
Maetani, Youji

× Maetani, Youji

WEKO 447880

Maetani, Youji

Search repository
Nakamoto, Yuji

× Nakamoto, Yuji

WEKO 447881

Nakamoto, Yuji

Search repository
Koyama, Takashi

× Koyama, Takashi

WEKO 447882

Koyama, Takashi

Search repository
Umeoka, Shigeaki

× Umeoka, Shigeaki

WEKO 447883

Umeoka, Shigeaki

Search repository
Tamai, Ken

× Tamai, Ken

WEKO 447884

Tamai, Ken

Search repository
Kido, Aki

× Kido, Aki

WEKO 447885

Kido, Aki

Search repository
Morisawa, Nobuko

× Morisawa, Nobuko

WEKO 447886

Morisawa, Nobuko

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 447887

Saga, Tsuneo

Search repository
Togashi, Kaori

× Togashi, Kaori

WEKO 447888

Togashi, Kaori

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 447889

en 佐賀 恒夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE: To evaluate improvements in image homogeneity in pelvic MR imaging at 3 Tesla (T) using two different dielectric pads. MATERIALS AND METHODS: A total of eight healthy females were scanned using a 3T MR scanner equipped with a body-array coil. Axial and sagittal fast spin-echo T2-weighted images (T2WI) (TR/TE = 3200 msec/94 msec), axial fast spin-echo T1-weighted images (T1WI) (TR/TE = 700 msec/11 msec), and sagittal half-Fourier acquisition single-shot turbo spin-echo (HASTE) images (TR/TE = 3000 msec/100 msec) were performed for pelvic imaging. Sequences were repeated with dielectric pads (consisting of either ultrasound [US] gel or water), and without pads. Three or four regions of interest (ROIs) were placed on fatty tissues and the ratio of minimum to maximum signal intensity (RSI) was calculated as a marker of image homogeneity. RESULTS: RSI was significantly higher on T2WI and T1WI when using dielectric pads than when no pad was used. A similar tendency was observed in RSI on HASTE. No significant difference was found between images with US gel pads and those with water pads. CONCLUSION: Dielectric pads consisting of either US gel or water are effective in improving image homogeneity of the pelvis on 3T MRI. (c) 2007 Wiley-Liss, Inc.
書誌情報 Journal of Magnetic Resonance Imaging : JMRI

巻 26, 号 6, p. 1572-1577, 発行日 2007-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 1053-1807
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:07:40.576214
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3