WEKO3
アイテム
The use of 3-(2-pyridyl)-5, 6-diphenyl-1, 2, 4-triazine as precolumn derivatizing reagent in HPLC determination for Fe(II) in natural samples
https://repo.qst.go.jp/records/45017
https://repo.qst.go.jp/records/450175f5a26a1-ca0d-4189-a686-9e5acd39cc95
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-11-12 | |||||
タイトル | ||||||
タイトル | The use of 3-(2-pyridyl)-5, 6-diphenyl-1, 2, 4-triazine as precolumn derivatizing reagent in HPLC determination for Fe(II) in natural samples | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Zhu, Weihuang
× Zhu, Weihuang× Wu, Fengchang× Zheng, Jian× Liu, Chongqiang× Wu Fengchang× 鄭 建 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The 3-(2-pyridyl)-5,6-diphenyl-1,2,4-triazine (PDT) was used for the first time as a precolumn derivatizing reagent applied in the high-performance liquid chromatography (HPLC) method with UV-detection for the Fe (II) determination. The Fe (II) reacts with PDT to form a magenta colored chelate in the presence of sodium dodecyl sulfate (SDS) and acetic acid-sodium acetate buffer solution medium of pH 4.65. The selection of maximum absorbance detect wavelength and the optimum composition of the organic modifier in the mobile phase were investigated in detail for the quantitative determination of Fe (II) using HPLC system. The formed Fe(II)-PDT chelate was satisfactorily separated from PDT on a Agilent Shim-pack ODS column (Eclipse XDB-C8,4.6x150mm) by isocratic elution with acetonitrile and 0.02 mol L-1 acetic acid-sodium acetate buffer solution (pH 4.65, containing 0.02% of SDS and 60x10-3 mol L-1 NaClO4) as mobile phase at a flow rate of 1 mL min-1, and monitored with a multiple wavelength detector. The detection limit (S/N =3) is 0.35 ng ml-1. Due to the excellent separation ability of HPLC, the innovative introduction of PDT as the precolumn derivatizing reagent, and the proper selection of the detect wavelength, the sensitivity of our newly developed HPLC method was enhanced remarkably compared to the common spectrophotometric methods. The developed HPLC method was successfully applied to the determination of Fe(II) in lake water samples. | |||||
書誌情報 |
Analytical Sciences 巻 23, 号 11, p. 1291-1296, 発行日 2007-11 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0910-6340 |