タイトル The use of 3-(2-pyridyl)-5, 6-diphenyl-1, 2, 4-triazine as precolumn derivatizing reagent in HPLC determination for Fe(II) in natural samples
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zhu, Weihuang

× Zhu, Weihuang

WEKO 447068

Zhu, Weihuang

Search repository
Wu, Fengchang

× Wu, Fengchang

WEKO 447069

Wu, Fengchang

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 447070

Zheng, Jian

Search repository
Liu, Chongqiang

× Liu, Chongqiang

WEKO 447071

Liu, Chongqiang

Search repository
Wu Fengchang

× Wu Fengchang

WEKO 447072

en Wu Fengchang

Search repository
鄭 建

× 鄭 建

WEKO 447073

en 鄭 建

Search repository
抄録
内容記述タイプ Abstract
内容記述 The 3-(2-pyridyl)-5,6-diphenyl-1,2,4-triazine (PDT) was used for the first time as a precolumn derivatizing reagent applied in the high-performance liquid chromatography (HPLC) method with UV-detection for the Fe (II) determination. The Fe (II) reacts with PDT to form a magenta colored chelate in the presence of sodium dodecyl sulfate (SDS) and acetic acid-sodium acetate buffer solution medium of pH 4.65. The selection of maximum absorbance detect wavelength and the optimum composition of the organic modifier in the mobile phase were investigated in detail for the quantitative determination of Fe (II) using HPLC system. The formed Fe(II)-PDT chelate was satisfactorily separated from PDT on a Agilent Shim-pack ODS column (Eclipse XDB-C8,4.6x150mm) by isocratic elution with acetonitrile and 0.02 mol L-1 acetic acid-sodium acetate buffer solution (pH 4.65, containing 0.02% of SDS and 60x10-3 mol L-1 NaClO4) as mobile phase at a flow rate of 1 mL min-1, and monitored with a multiple wavelength detector. The detection limit (S/N =3) is 0.35 ng ml-1. Due to the excellent separation ability of HPLC, the innovative introduction of PDT as the precolumn derivatizing reagent, and the proper selection of the detect wavelength, the sensitivity of our newly developed HPLC method was enhanced remarkably compared to the common spectrophotometric methods. The developed HPLC method was successfully applied to the determination of Fe(II) in lake water samples.
書誌情報 Analytical Sciences

巻 23, 号 11, p. 1291-1296, 発行日 2007-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0910-6340
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:08:39.985232
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3