WEKO3
アイテム
Measurements of deposited dose with induced beta+ activity in proton and heavy-ion therapy
https://repo.qst.go.jp/records/45001
https://repo.qst.go.jp/records/45001eb8421a0-a6b2-4aff-a76f-200b16145f2f
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-10-23 | |||||
タイトル | ||||||
タイトル | Measurements of deposited dose with induced beta+ activity in proton and heavy-ion therapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Inaniwa, Taku
× Inaniwa, Taku× Kohno, Toshiyuki× Tomitani, Takehiro× Urakabe, Eriko× Satou, Shinji× Kanazawa, Mitsutaka× Kanai, Tatsuaki× 稲庭 拓× 河野 俊之× 富谷 武浩× 佐藤 眞二× 金澤 光隆× 金井 達明 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | For the effective utilization of the favorable properties of heavy-ion beams in cancer treatment, it is important to evaluate the range of incident ions and the deposited dose distribution in a patient's body. For this purpose, the utilization of positron emitters induced in therapeutic irradiation is, at present, the only feasible method for in situ and non-invasive monitoring of heavy-ion therapy. In this study, we performed irradiation experiments with three species of ions to a water target, and the annihilation gamma-ray distributions were obtained with a positron camera. We applied the maximum likelihood estimation (MLE) method for the detected distributions to derive the range of incident ions and the deposited dose distribution in the target. As a result, the ranges were determined with a difference between the MLE range RMLE and the experimental range Rexp less than 1.1 mm. The good agreement between the estimated dose distribution with the MLE method and the measured one implies that a deposited dose distribution in a target could be estimated from a detected annihilation gamma-ray distribution. | |||||
書誌情報 |
Nuclear Instruments & Methods in Physics Research Section A 巻 580, 号 3, p. 1140-1143, 発行日 2007-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nima.2007.06.072 |