Measurements of deposited dose with induced beta+ activity in proton and heavy-ion therapy

https://repo.qst.go.jp/records/45001
https://repo.qst.go.jp/records/45001
eb8421a0-a6b2-4aff-a76f-200b16145f2f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-10-23
タイトル
タイトル Measurements of deposited dose with induced beta+ activity in proton and heavy-ion therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, Taku

× Inaniwa, Taku

WEKO 446920

Inaniwa, Taku

Search repository
Kohno, Toshiyuki

× Kohno, Toshiyuki

WEKO 446921

Kohno, Toshiyuki

Search repository
Tomitani, Takehiro

× Tomitani, Takehiro

WEKO 446922

Tomitani, Takehiro

Search repository
Urakabe, Eriko

× Urakabe, Eriko

WEKO 446923

Urakabe, Eriko

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 446924

Satou, Shinji

Search repository
Kanazawa, Mitsutaka

× Kanazawa, Mitsutaka

WEKO 446925

Kanazawa, Mitsutaka

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 446926

Kanai, Tatsuaki

Search repository
稲庭 拓

× 稲庭 拓

WEKO 446927

en 稲庭 拓

Search repository
河野 俊之

× 河野 俊之

WEKO 446928

en 河野 俊之

Search repository
富谷 武浩

× 富谷 武浩

WEKO 446929

en 富谷 武浩

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 446930

en 佐藤 眞二

Search repository
金澤 光隆

× 金澤 光隆

WEKO 446931

en 金澤 光隆

Search repository
金井 達明

× 金井 達明

WEKO 446932

en 金井 達明

Search repository
抄録
内容記述タイプ Abstract
内容記述 For the effective utilization of the favorable properties of heavy-ion beams in cancer treatment, it is important to evaluate the range of incident ions and the deposited dose distribution in a patient's body. For this purpose, the utilization of positron emitters induced in therapeutic irradiation is, at present, the only feasible method for in situ and non-invasive monitoring of heavy-ion therapy. In this study, we performed irradiation experiments with three species of ions to a water target, and the annihilation gamma-ray distributions were obtained with a positron camera. We applied the maximum likelihood estimation (MLE) method for the detected distributions to derive the range of incident ions and the deposited dose distribution in the target. As a result, the ranges were determined with a difference between the MLE range RMLE and the experimental range Rexp less than 1.1 mm. The good agreement between the estimated dose distribution with the MLE method and the measured one implies that a deposited dose distribution in a target could be estimated from a detected annihilation gamma-ray distribution.
書誌情報 Nuclear Instruments & Methods in Physics Research Section A

巻 580, 号 3, p. 1140-1143, 発行日 2007-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2007.06.072
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:08:50.191479
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3