ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Carbon ion therapy for ocular melanoma: planning orthogonal two-port treatment

https://repo.qst.go.jp/records/44978
https://repo.qst.go.jp/records/44978
b202908d-192c-413d-8d1e-ad1a641a0aa0
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-09-19
タイトル
タイトル Carbon ion therapy for ocular melanoma: planning orthogonal two-port treatment
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ito, Hiroko

× Ito, Hiroko

WEKO 446646

Ito, Hiroko

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 446647

Kanai, Tatsuaki

Search repository
Minohara, Shinichi

× Minohara, Shinichi

WEKO 446648

Minohara, Shinichi

Search repository
Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 446649

Tsuji, Hiroshi

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 446650

Tsujii, Hirohiko

Search repository
伊藤 浩子

× 伊藤 浩子

WEKO 446651

en 伊藤 浩子

Search repository
金井 達明

× 金井 達明

WEKO 446652

en 金井 達明

Search repository
蓑原 伸一

× 蓑原 伸一

WEKO 446653

en 蓑原 伸一

Search repository
辻 比呂志

× 辻 比呂志

WEKO 446654

en 辻 比呂志

Search repository
辻井 博彦

× 辻井 博彦

WEKO 446655

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 We recently started orthogonal two-port carbon ion therapy for choroidal
melanoma with the intent to reduce the incidence of radiation complications
that occur with mono-port therapy. Treatment planning techniques involving
therapeutic beam characteristics are described here. The vertical (140 MeV/u) and horizontal (170 MeV/u) carbon ion beams from the synchrotron at the NIRS were shaped, using the passive beam delivery system, to irradiate the target volume. The range modulating ridge filters were designed to produce spread-out Bragg peaks (SOBPs) with a region of uniform HMV-I cell killing. The apertures and range compensators were designed for individual patients. A commercial treatment planning system, which was customized to our general carbon ion therapy, was tested for applicability to this treatment. Dose distributions were calculated with either a broad beam or a pencil beam algorithm using parameters determined by measurements and calculations.We evaluated the accuracy of the system software features, and replaced or added some other features to the software. The system was used for 12 patients during the past year. For nine patients two-port treatment was assessed to be more effective than mono-port therapy and these patients were treated with two
fractions of vertical beams and three fractions of horizontal beams.
書誌情報 Physics in Medicine and Biology

巻 52, 号 17, p. 5341-5352, 発行日 2007-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
識別子タイプ DOI
関連識別子 10.1088/0031-9155/52/17/016
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:09:06.413129
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3