  1. 原著論文

CELLULAR SIGNAL TRANSDUCTION EVENTS AS A FUNCTION OF LINEAR ENERGY TRANSFER(LET)

https://repo.qst.go.jp/records/44974
https://repo.qst.go.jp/records/44974
1407542f-c584-44ab-b885-9e0417987a6c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-09-11
タイトル
タイトル CELLULAR SIGNAL TRANSDUCTION EVENTS AS A FUNCTION OF LINEAR ENERGY TRANSFER(LET)
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Christoph, Furweger

× Christoph, Furweger

WEKO 446602

Christoph, Furweger

Search repository
Hajek, Michael

× Hajek, Michael

WEKO 446603

Hajek, Michael

Search repository
Vana, Norbert

× Vana, Norbert

WEKO 446604

Vana, Norbert

Search repository
Kodym, R

× Kodym, R

WEKO 446605

Kodym, R

Search repository
Okayasu, Ryuichi

× Okayasu, Ryuichi

WEKO 446606

Okayasu, Ryuichi

Search repository
Christoph Furweger

× Christoph Furweger

WEKO 446607

en Christoph Furweger

Search repository
Hajek Michael

× Hajek Michael

WEKO 446608

en Hajek Michael

Search repository
岡安 隆一

× 岡安 隆一

WEKO 446609

en 岡安 隆一

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to obtain a deeper insight into the molecular mechanism controlling the cellular response to high-linear energy transfer (LET) radiation, the number and size of pATM (S1981) and gammaH2AX foci were compared in cultures of diploid human fibroblasts after exposure to charged particles of varying species, energy and LET at the NIRS-HIMAC-facility (Chiba, Japan). Particle LET ranged from 2.2 to 300 keV/mu, and a low fluence of 7.3 x 10(4) cm(-2) was chosen. Therefore, about 1 out of 7 nuclei was traversed by a particle. Doses and LET were verified with thermoluminescence detectors (LiF:Mg, Ti) evaluated according to the high temperature ratio method. Two hours after irradiation, fibroblasts were fixed and the subcellular distribution of pATM (S1981) and gammaH2AX was visualised by immunofluorescence or histochemical staining using phosphorylation-specific antibodies. It was found that the number of pATM (S1981) foci per nucleus was higher after exposure to higher-LET particles. Irradiation with the two highest LET beams (Fe-ions, 197 and 300 keV/mu) gave a significant increase in the number of pATM foci, whereas ions with an LET lower than 30 keV/mum yielded similar numbers of pATM foci compared with unirradiated control samples. These data show that the early cellular response to high-LET radiation is modulated by the energy deposition of the particle. Therefore, the correlation between the microdosimetric aspect of energy deposition and biologic consequences at low radiation doses deserves further study
書誌情報 Radiation Protection Dosimetry

巻 126, 号 1/4, p. 418-422, 発行日 2007
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
戻る
0
views
See details
Views