  1. 原著論文

Rapid fingerprinting of 239Pu and 240Pu in environmental samples with high U levels using on-line ion chromatography coupled with high-sensitivity quadrupole ICP-MS detection

https://repo.qst.go.jp/records/44958
https://repo.qst.go.jp/records/44958
7521f793-8de0-4d54-8bb2-bfc918fd9d63
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-08-28
タイトル
タイトル Rapid fingerprinting of 239Pu and 240Pu in environmental samples with high U levels using on-line ion chromatography coupled with high-sensitivity quadrupole ICP-MS detection
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Epov, Vladimir

× Epov, Vladimir

WEKO 446466

Epov, Vladimir

Search repository
Douglas, Evans R

× Douglas, Evans R

WEKO 446467

Douglas, Evans R

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 446468

Zheng, Jian

Search repository
F, X Donard O

× F, X Donard O

WEKO 446469

F, X Donard O

Search repository
Yamada, Masatoshi

× Yamada, Masatoshi

WEKO 446470

Yamada, Masatoshi

Search repository
鄭 建

× 鄭 建

WEKO 446471

en 鄭 建

Search repository
山田 正俊

× 山田 正俊

WEKO 446472

en 山田 正俊

Search repository
抄録
内容記述タイプ Abstract
内容記述 A simple, rapid on-line analytical method for the determination of plutonium (Pu) isotopes in soil and sediment samples was developed. Microwave leaching was used to extract Pu from the major sample matrix. L-ascorbic acid was found to be the most appropriate agent to convert all the Pu to Pu(IV) for chromatography. Flow injection chromatography using TEVA resin was optimized to separate, preconcentrate and elute Pu from other constituents of the sample including 238U. An APEX desolvation unit with a PEEK Mira Mist nebulizer was used to minimize clogging and hydride interferences. The advantage of using a high sensitivity quadrupole ICP-MS instrument for Pu detection was demonstrated. The detection limit was found to be 3 and 0.3 pg kg-1 for 239Pu and other Pu isotopes, respectively, while for 239+240Pu it was 10 mBq kg-1. To demonstrate the applicability of the method, Pu activities and atom ratios were measured for different sediments from the northern Asian region.
書誌情報 Journal of Analytical Atomic Spectrometry

巻 22, 号 9, p. 1131-1137, 発行日 2007-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 0267-9477
戻る
0
views
See details
Views