ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Effect of multislice acquisition on T1 and T2 measurements of articular cartilage at 3T

https://repo.qst.go.jp/records/44943
https://repo.qst.go.jp/records/44943
89c6d212-7c48-4ce4-a713-c2d47e60c4c5
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-08-15
タイトル
タイトル Effect of multislice acquisition on T1 and T2 measurements of articular cartilage at 3T
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Watanabe, Atsuya

× Watanabe, Atsuya

WEKO 446316

Watanabe, Atsuya

Search repository
Boesch, Chris

× Boesch, Chris

WEKO 446317

Boesch, Chris

Search repository
Obata, Takayuki

× Obata, Takayuki

WEKO 446318

Obata, Takayuki

Search repository
E., Anderson Suzanne

× E., Anderson Suzanne

WEKO 446319

E., Anderson Suzanne

Search repository
渡辺 淳也

× 渡辺 淳也

WEKO 446320

en 渡辺 淳也

Search repository
小畠 隆行

× 小畠 隆行

WEKO 446321

en 小畠 隆行

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose
The aim of this study was to investigate the effect of magnetization transfer on multislice T1 and T2 measurements of articular cartilage.
\nMaterials and Methods
A set of phantoms with different concentrations of collagen and contrast agent (Gd-DTPA2-) were used for the in vitro study. A total of 20 healthy knees were used for the in vivo study. T1 and T2 measurements were performed using fast-spin-echo inversion-recovery (FSE-IR) sequence and multi-spin-echo (MSE) sequence, respectively, in both in vitro and in vivo studies. We investigated the difference in T1 and T2 values between that measured by single-slice acquisition and that measured by multislice acquisition.
\nResults
Regarding T1 measurement, a large drop of T1 in all slices and also a large interslice variation in T1 were observed when multislice acquisition was used. Regarding T2 measurement, a substantial drop of T2 in all slices was observed; however, there was no apparent interslice variation when multislice acquisition was used.
\nConclusion
This study demonstrated that the adaptation of multislice acquisition technique for T1 measurement using FSE-IR methodology is difficult and its use for clinical evaluation is problematic. In contrast, multislice acquisition for T2 measurement using MSE was clinically applicable if inaccuracies caused by multislice acquisition were taken into account.
書誌情報 Journal of Magnetic Resonance Imaging : JMRI

巻 26, 号 1, p. 109-117, 発行日 2007-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 1053-1807
DOI
識別子タイプ DOI
関連識別子 10.1002/jmri.20962
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:09:31.142006
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3