Magnitude and effects of x-ray scatter in a 256-slice CT scanner

https://repo.qst.go.jp/records/44862
https://repo.qst.go.jp/records/44862
b63c5d8a-c483-4d57-b894-884cea3583a2
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-06-01
タイトル
タイトル Magnitude and effects of x-ray scatter in a 256-slice CT scanner
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Endo, Masahiro

× Endo, Masahiro

WEKO 445493

Endo, Masahiro

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 445494

Mori, Shinichiro

Search repository
Tsunoo, Takanori

× Tsunoo, Takanori

WEKO 445495

Tsunoo, Takanori

Search repository
Miyazaki, Hiroaki

× Miyazaki, Hiroaki

WEKO 445496

Miyazaki, Hiroaki

Search repository
遠藤 真広

× 遠藤 真広

WEKO 445497

en 遠藤 真広

Search repository
森 慎一郎

× 森 慎一郎

WEKO 445498

en 森 慎一郎

Search repository
角尾 卓紀

× 角尾 卓紀

WEKO 445499

en 角尾 卓紀

Search repository
抄録
内容記述タイプ Abstract
内容記述 We developed a prototype 256-slice CT scanner that employs continuous rotation of a cone-beam with a larger cone angle than conventional multidetector CTs (MDCT) to ensure a wide field of view. However, a larger cone angle may result in image deterioration due to increased x-ray scatter. Scattered radiation causes the detected signals to deviate from the true measurement of primary x-ray intensity and may result in artifacts (e.g., cupping and streak artifacts), quantitative inaccuracy in reconstructed CT number, and degradation of contrast-to-noise ratio (CNR). To reduce the effects of scatter, the 256-slice scanner incorporates an antiscatter collimator. Here, we estimated the magnitude of x-ray scatter in the prototype 256-slice CT scanner under clinical scan conditions and quantified the effects of this scatter on CT number accuracy, image noise, uniformity, and low contrast detectability. Although most experiments were performed with the antiscatter collimator, we also estimated the magnitude of x-ray scatter without the collimator to evaluate the scatter rejection efficiency of the collimator. The scatter-to-primary energy fluence ratio (SPR) without the collimator increased as cone angle increased, with estimated values of 49.7% for a 138 mm beam width with a phantom of 200 mm diameter, and 78.5% for a 320 mm diameter phantom. Estimated SPR was drastically decreased with the collimator, with an SPR reduction rate (ratio of SPR with and without the collimator) of 12.7% and 16.8% for the 200 and 320 mm diameter phantoms, respectively. The reduction in x-ray scatter by the collimator resulted in a considerable reduction in scatter effects. The measured uniformity was good and was independent of scatter amount. Although scatter still affected CT number accuracy, this could be corrected by rescaling. Further, although the CNR was decreased, in theory at least, the change was so subtle that it had no substantial effect on low-contrast detectability.
書誌情報 Medical Physics

巻 33, 号 9, p. 3359-3368, 発行日 2006-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 0094-2405
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:10:28.423091
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3