ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Projection-data based temporal maximum attenuation computed tomography: determination of internal target volume for lung cancer against intra-fraction motion

https://repo.qst.go.jp/records/44839
https://repo.qst.go.jp/records/44839
f9dba1bf-f806-4fc0-bc3b-2994a5f28724
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-05-02
タイトル
タイトル Projection-data based temporal maximum attenuation computed tomography: determination of internal target volume for lung cancer against intra-fraction motion
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 445305

Mori, Shinichiro

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 445306

Kanematsu, Nobuyuki

Search repository
Asakura, Hiroshi

× Asakura, Hiroshi

WEKO 445307

Asakura, Hiroshi

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 445308

Endo, Masahiro

Search repository
森 慎一郎

× 森 慎一郎

WEKO 445309

en 森 慎一郎

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 445310

en 兼松 伸幸

Search repository
遠藤 真広

× 遠藤 真広

WEKO 445311

en 遠藤 真広

Search repository
抄録
内容記述タイプ Abstract
内容記述 The concept of internal target volume (ITV) is highly significant in radiotherapy for the lung, an organ which is hampered by organ motion. To date, different methods to obtain the ITV have been published and are therefore available. To define ITV, we developed new method by adapting a time filter to the four-dimensional CT scan technique (4DCT) that is projection-data processing [4D projection data maximum attenuation (4DPM)], and compared them with a reconstructed image processing [4D image maximum intensity projection (4DIM)] using a phantom and in clinical evaluations. 4DIM and 4DPM captured accurate maximum intensity volume (MIV) that is tumor encompassing volume, easily. Although 4DIM increased the CT number 1.8 times higher than 4DPM, 4DPM provided the original tumor CT number for MIV via a reconstruction algorithm. In the patient with lung fibrosis honeycomb, MIV with 4DIM is 0.7 cm larger than that for cine imaging in the cranio-caudal direction. 4DPM therefore provided an accurate MIV independent of patient characteristics and reconstruction conditions. These findings indicate the usefulness 4DPM in determining ITV in radiotherapy.
書誌情報 Physics in Medicine and Biology

巻 52, 号 4, p. 1027-1038, 発行日 2007-02
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:10:44.573970
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3