ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Confirming the existence of five peaks in 129Xe rat head spectra

https://repo.qst.go.jp/records/44835
https://repo.qst.go.jp/records/44835
89ac36b0-b5d0-488d-b261-e1bf9d6613b7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-04-24
タイトル
タイトル Confirming the existence of five peaks in 129Xe rat head spectra
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kershaw, Jeffrey

× Kershaw, Jeffrey

WEKO 445265

Kershaw, Jeffrey

Search repository
Nakamura, Kazuhiro

× Nakamura, Kazuhiro

WEKO 445266

Nakamura, Kazuhiro

Search repository
Wakai, Atsushi

× Wakai, Atsushi

WEKO 445267

Wakai, Atsushi

Search repository
Kanno, Iwao

× Kanno, Iwao

WEKO 445268

Kanno, Iwao

Search repository
et.al

× et.al

WEKO 445269

et.al

Search repository
Kershaw Jeffrey

× Kershaw Jeffrey

WEKO 445270

en Kershaw Jeffrey

Search repository
中村 和浩

× 中村 和浩

WEKO 445271

en 中村 和浩

Search repository
若井 篤志

× 若井 篤志

WEKO 445272

en 若井 篤志

Search repository
菅野 巖

× 菅野 巖

WEKO 445273

en 菅野 巖

Search repository
抄録
内容記述タイプ Abstract
内容記述 A series of experiments were performed to investigate why two peaks (D and E) of the five dissolved phase peaks in hyperpolarized 129Xe rat head spectra appeared inconsistently in previous work. Specifically, spectra were acquired under conditions of various shim states, anaesthetics, and arterial ligation. The shimming experiments showed that slice-shimming can be used to improve resolution of the dissolved phase peaks, but even so, subtle changes in the shim state that may dramatically alter the shape of peak E remain poorly understood. Also, the inability to shim gas spaces and tissue simultaneously may explain why inconsistent chemical shift values have been reported in the literature. A possible solution for this problem is suggested. The results of pre- and postligation spectra from the same animal indicated that two peaks (A and E) originate from brain. Changing the anaesthetic was found to have no effect on the number of dissolved peaks in xenon spectra.
書誌情報 Magnetic Resonance in Medicine

巻 57, 号 4, p. 791-797, 発行日 2007-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0740-3194
DOI
識別子タイプ DOI
関連識別子 10.1002/mrm.21186
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:10:47.362882
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3