Properties of the prototype 256-row (cone beam) CT scanner

https://repo.qst.go.jp/records/44832
https://repo.qst.go.jp/records/44832
758a74b4-d2d4-4687-8340-52c4fba14bd7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-04-19
タイトル
タイトル Properties of the prototype 256-row (cone beam) CT scanner
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 445228

Mori, Shinichiro

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 445229

Endo, Masahiro

Search repository
Obata, Takayuki

× Obata, Takayuki

WEKO 445230

Obata, Takayuki

Search repository
Tsunoo, Takanori

× Tsunoo, Takanori

WEKO 445231

Tsunoo, Takanori

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 445232

Kandatsu, Susumu

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 445233

Tanada, Shuji

Search repository
森 慎一郎

× 森 慎一郎

WEKO 445234

en 森 慎一郎

Search repository
遠藤 真広

× 遠藤 真広

WEKO 445235

en 遠藤 真広

Search repository
小畠 隆行

× 小畠 隆行

WEKO 445236

en 小畠 隆行

Search repository
角尾 卓紀

× 角尾 卓紀

WEKO 445237

en 角尾 卓紀

Search repository
神立 進

× 神立 進

WEKO 445238

en 神立 進

Search repository
棚田 修二

× 棚田 修二

WEKO 445239

en 棚田 修二

Search repository
抄録
内容記述タイプ Abstract
内容記述 We evaluated Feldkamp artifacts, which are specific to cone-beam CT, in phantom and clinical studies using the 256 multi-detector-row CT (256MDCT), and compared the reconstruction accuracy of axial and helical scans.
Image noise, slice sensitivity profile (SSP) and artifacts with the 256MDCT were evaluated using a phantom and the results were compared to those with a 64MDCT. We also examined chest and abdomen scans produced with the 256MDCT in volunteers.
For the axial scan, Feldkamp artifacts were visualized as high-frequency streak-like artifacts that are oriented horizontally at the edge of the scan region in the phantom study. Similar results were obtained with the volunteers in soft-tissue regions near either bony structures or air pockets. Feldkamp artifacts with the 256MDCT can lead to misdiagnosis if not correctly identified and minimized via helical scanning. Image noise was less for axial than helical scans, while SSP was better with helical than axial scans.
Feldkamp artifacts observed in the 256MDCT images, however, did not generally affect the interpretation of images. The 256MDCT promises more accurate diagnosis, and will provide volumetric cine images of wider cranio-caudal coverage, enabling new applications of CT.
書誌情報 European Radiology

巻 16, 号 9, p. 2100-2108, 発行日 2006-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 0938-7994
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:10:49.643149
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3